Ccb02-100Bt Industrial Charge Base Product Specifications - Honeywell Xenon 1910 User Manual

Hide thumbs Also See for Xenon 1910:
Table of Contents

Advertisement

Parameter (Continued)
Range
Data Rate
Temperature Ranges:
Operating
Battery Charge
Storage without battery
Humidity
Mechanical Drop
Vibration
ESD Sensitivity

CCB02-100BT Industrial Charge Base Product Specifications

Parameter
Dimensions (Typical):
Height
Length
Width
Weight
Voltage:
Current Draw:
Host Terminal Port
Aux Power Port
Charge Time
Radio:
Frequency
Range
Data Rate
Temperature Ranges:
Operating
Battery Charge
Storage without battery
Humidity
Mechanical Drop
Vibration
ESD Sensitivity
Specification
33 ft. (10 m) typical
Up to 1 MBps
32 F to +122 F (0 C to +50 C)
41 F to +104 F (5 C to +40 C)
-40 F to +158 F (-40 C to +70 C)
Up to 95% non-condensing
Operational after 50 drops from 3.28 feet
(1 m) to concrete
5G Peak from 22Hz to 300Hz
Up to 15kV direct air
Up to 8 kV indirect coupling plane
Specification
2.6 in. (66mm)
9.8 in. (248.9mm)
4.05 in. (102.9cm)
10.05 oz. (285g)
4.5 to 5.5 volts
500mA
1A
5 hours
2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v.2.1
330 ft. (100m) typical
Up to 1 MBps
-4 F to +122 F (-20 C to +50 C)
41 F to +104 F (5 C to +40 C)
-40 F to +158 F (-40 C to +70 C)
Up to 95% non-condensing
Operational after 50 drops from 3.94 feet
(1.2m) to concrete
Complies with MIL-STD-810G, Method 514.6, Annex C
Up to 20kV direct air
Up to 8 kV indirect coupling plane
13 - 5