10
DIAGNOSTIC TEST
Test 10
Measurement condition : Check if they are working when connected to power supply.
Is the product leveled?
(Check shaking / tilt )
ta ~ ta~ ta~ sound)
※Check the status of the actions Sensor
- Drum Light + Buzzer 3 when entering
Pressing enter, Once again press the same key
fot three seconds to escape.
- Turn the Jog Dial in data view state data can be
checked as shown below.
- Not to enter the Child lock status.
- Apply the model : Only Touch LED model.
NO
The course
Show details
1
Refresh
Humidity values
2
Skin Care
Low Temp
3
Jeans
Comp Temp
4
Bulky Item
T_heater (High Thermistor)
5
Easy Care
Eva in Temp
6
Mixed Fabric
7
Cotten
8
Sports Wear
Sump Water Level
9
Quick Dry
Drain Pump RPM
10
Delicate
LEV Pulse
11
Wool
Main PGM Tool
12
Rack Dry
Main Version
Note: The roler noise (dung dung dung) at the initial operation, and pump and water flowing noise during auto cleaning
product. If noise of metal materials bumping each other occurs, check if screw is properly locked or if it is properly assembled.
Adjust product leveling
(Refer to how to leveling, Page 10)
2) After Comp on, check corresponding
thermistor temp.
Is Belt properly assembled to Pulley?
Is Journal Bearing grease properly
Sprayed?
( Refer to exploded view ,
Refer to picture C page35 )
Replace Journal bearing (D122)
Adjust pipe position to insure minimum
5mm gap with pipe or mold
Adjust pipe position to insure minimum
5mm gap with pipe or mold
Refer to picture A , page35
Replace real seal (D152)
33
Is the washer between Drum and
Rear cover flat?
( Refer to picture D , page35 )