INSTALLATION INSTRUCTIONS FOR
ELV1/PSPLV510
Programmable Line Voltage Thermostat
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
WARNING: Use Energizer
®
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
For Use On:
• Heating Only 120/240 Vac Single
Pole Applications
• Baseboard, Ceiling Cable and
other Radiant Heat
Not For Use On:
• Double Pole Applications
• Heating/Cooling or Cooling Only
• Low Voltage (24Vac) Systems
Electrical Rating
16A at 120/240 Vac
1900W at 120Vac
(Non-Inductive)
3800W at 240 Vac
(Non-Inductive)
Temperature Differential
• ±1°F Factory Preset; Adjustable
43331-04
or DURACELL
®
Alkaline Batteries Only.
Batteries
• Two Energizer
®
or DURACELL
"AA" alkaline batteries
(not included)
Programming
• Preprogrammed - 4 Periods per
day
• 5 / 2 Programming
• Weekdays/Weekends can be
different
• °F / °C Changeable
• Temporary Temperature Override
• Vacation Hold
Dimensions
• 4.7" T x 2.7" W x 2.4" D
• 1.4" D from wall surface
Wall Plate
• 4.8" W x 5.0" H Wallplate
Included
© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
INSTALLATION
• This Thermostat is a line voltage (120 / 240 Vac) control. Do not
install it unless you are completely familiar with house wiring. If
improperly handled, there can be a risk of electric shock hazard
which may cause serious injury or death.
• The thermostat is rated for normal full load current on a dual
residential 20A circuit breaker or fuse block. Do not use on circuits
protected by higher-rated over-current protection devices. Some
sustained fault conditions can cause product failure.
• Do NOT connect to voltage different from the device rating.
• Disconnect power supply before making wire connections to
prevent electrical shock or equipment damage.
• All wiring must comply with applicable codes and ordinances.
• Thermostats are designed to be used with appliances having a limit
control.
• Maximum load for this thermostat MUST NOT EXCEED 3800W,
otherwise a potential fire hazard exists.
Location:
Install a vertical switch box for mounting the thermostat
approximately 1.5 m (5 ft.) above the floor on an inside wall where the
thermostat will be exposed to average room temperature.
thermostat must be placed away from concealed warm or cold water
pipes, air ducts, or drafts from hallways, fireplaces or stairways to
sense temperature properly. Do not place the thermostat above the
heater.
WIRING
1. Disconnect power while installing.
thermostat is rated for the voltage and amperage load to be
controlled.
2. Remove the cover by carefully pressing the button at the bottom of
®
the thermostat and swinging the body up and away.
3. When replacing an old line voltage wall thermostat, remove it
carefully to avoid damage to the insulation on the wiring. Check the
old insulation for cracks, nicks, or fraying and apply certified
electrical tape where necessary to achieve adequate insulation, or
replace the wires in an approved fashion.
4. Attach the wires with solderless wire connectors (provided). Be
sure that all wire connectors are tight.
W A R N I N G
C A U T I O N
Double check that the
The
1

Advertisement

loading

Summary of Contents for Lux Products ELV1/PSPLV510

  • Page 1 INSTALLATION INSTRUCTIONS FOR ELV1/PSPLV510 Programmable Line Voltage Thermostat LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA WARNING: Use Energizer ® or DURACELL ® Energizer ® is a registered trademark of Eveready Battery Company, Inc. DURACELL ® is a registered trademark of The Gillette Company, Inc.
  • Page 2 To correct the display, see SETTING THE TIME AND DAY. © COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED temperature. It also displays the day of the week and the currently active control program that is controlling the temperature: MORN, DAY, EVE, or NIGHT.
  • Page 3: Advanced Features

    • To change to Celsius, move the top dip switch to the right. • To change to a 24HR clock, move the bottom dip switch to the right. • Press the reset key on the front of the thermostat for the changes to take effect.

This manual is also suitable for:

Elv1Psplv510