WARNING:
All aspects of the installation must conform with the requirements of the standard North
American wiring rules, as well as your local electrical and building codes and regulations,
and any other applicable requirements or conditions of your local power supply authority.
A licensed electrician must perform the electrical work when installing this appliance. The
supply cable and fuse rating must be suitable for the appliance.
240 Volt 60Hz 30AMP single/40AMP double service
208 Volt 60Hz 20AMP single/40 AMP double service

SEO60 Single Oven

Condominium Electrical Requirements: 208 Volt, 60hZ, 2780 Watt, 20 AMP
Residential Electrical Requirements: 240 Volt, 60hZ, 3660 Watt, 20 AMP

SEO76 Single Oven

Condominium Electrical Requirements: 208 Volt, 60hZ, 3460 Watt, 20 AMP
Residential Electrical Requirements: 240 Volt, 60hZ, 4580 Watt, 30 AMP

DEO60-L Double Oven

Condominium Electrical Requirements: 208 Volt, 60hZ, 4550 Watt, 30 AMP
Residential Electrical Requirements: 240 Volt, 60hZ, 6050 Watt, 30 AMP
DEO76-L Double Oven
Condominium Electrical Requirements: 208 Volt, 60hZ, 6000 Watt, 40 AMP
Residential Electrical Requirements: 240 Volt, 60hZ, 8150 Watt, 40 AMP
WARNING:
AEG ovens are supplied with a 5' long electrical cable and must be hard wired to the
electrical supply. AEG ovens use Red and Black live wires and Green for ground. A
licensed electrician must connect the armour cable and 3 wires into the electrical
connection box. The white, or Neutral wire is not used, and must be capped using a
marette.
To avoid power borne interference, this appliance must be installed individually on a separate and
distinct final sub-circuit.
Note:
To the electrician – please ensure sufficient supply cable is provided to allow the appliance to be
removed from the cavity should any servicing be necessary. This will also allow easy connection
of the supply.