Receiving (Handset); Battery Low (Handset) - Sanyo CLA-1380 Service Manual

Cordless telephone answering system
Hide thumbs Also See for CLA-1380:
Table of Contents

Advertisement

ADJUSTMENT
3. RECEIVING
(HANDSET)
Test Equipment
(1)
FM SSG (50
ohm,
OPEN type)
(2) AC Voltmeter
(3)
DC Power Supply (DC 3.8V)
(4)
Distortion
meter
(6)
Digital voltmeter
1. RXIF
(1)
(2)
(3)
Connect
a FM SSG (1 kHz mod.,
2.0 kHz dev.,
30.100 MHz, 46dBP) to the ANT test pin (CN151).
Connect an AF-VTVM
and distortion
meter in parallel
and terminate
a 150 ohm dummy
load across the SP
terminal.
Adjust T351 so that the reading
of the AF voltmeter
is maximum
level and minimum
distortion
at distor-
tion meter.
Unit Condition
(1)
(2)
Change
to channel
6 by pushing
"6",
followed
by
%"
button.
Connect IC351 pin 16 to ground by electrical
capaci-
tor (10,uF / 16 V). ------ HCC : OFF Mode
2.
RX
RF
(1)
Connect
a FM SSG (46 dBP + O dBP) to the ANT
test pin (CN151).
(2) Adjust T151 so that the reading of the distortion
me-
ter is minimum
distortion
(less than IOYO).
3. RX AF LEVEL
(1) Connect
a FM SSG (O dBP -46
dB~) to the ANT
test pin (CN151).
(2) Adjust VR352 so that the reading of the AF voltmeter
'"
is 50 mV ~ 10 mV at SPEAKER output.
STEP
CONDITION
ADJUST
I
ADJUST
VALUE
I SPECIFICATION
]
1.
RXIF
FM SSG :
46dB/
T351
MAXIMUM
LEVEL
------
2.
RX RF
FM SSG :
OdB~
T151
MINIMUM
DISTORTION
less than
10%
3.
RX AF LEVEL
FM SSG
: 46dBfl
VR352
50 mV
50mV
flOmV
CN151
Unit
L151 (DPX
SIDE)
Sp
+
7
FM SSG
IC351
Voltmeter
GND
Test
Pin 16
GND
Mod. :1
kHz
)
+
Dev. :2.0
kHz
Distortion
Meter
A
10,UFII6V
4. BATTERY
LOW (HANDSET)
Adjust
Test
Equipment
(1)
Digital
Voltmeter
(2)
DC Power Supply
Unit Condition
(1)
(2)
(3)
(4)
Disconnect
Ni-Cd battery
ply terminal.
Connect
digital voltmeter
and ground.
feed 3.8V from power sup-
(1)
Adjust VR351 to obtain reading of OV at digital volt-
meter.
(2)
Confirm at power supply as follows.
Power supply
Voltmeter
reading
3.35V
3.5V
<0.5V
>3.OV
across IC351 pin 36 (Hot)
I
I
I
I
Change DC power supply from 3.8V + 3.4V.
IC351 Pin36
Give a full turn to VR351 at counterclockwise.
I
Digital
Voltmeter
I
GND
t
Unit
–21–

Advertisement

Table of Contents
loading

Table of Contents