Daisy Chaining

To manage more devices, up to 5 additional iPoMan II-1200s
can be daisy chained to the first unit. Follow instructions below
to set up a daisy chained installation.
1. For each iPoMan II-1200 that you add to the chain, use USB
cables to connect it to the parent iPoMan II-1200's C-Link Port.
The upper C-Link port(
) of child iPoMan II is connected to
lower C-Link port(
) of its parent iPoMan II and the lower C-
Link port(
) of the lowest level iPoMan II is connected to the
highest level parent's upper C-Link port(
) to form a
cyclic(ring) structure as illustrated in the following figure.
2.
The daisy chained installation can operate in Auto mode or Manual
mode. Use Daisy-chaining Mode DIP Switch (C-link DIP) to set the
operation mode.
Auto mode: For the master iPoMan II-1200, set all the DIP switches
of the C- link to ON by moving all the switches downward; for all the
other iPoMan II-1200s (slave iPoMan IIs) in the Daisy Chain, set all

Hide quick links: