Table Of Contents; Specifications - COZY VC201A-H Installation And Operating Instructions Manual

Gas-fired vented room heater
Table of Contents

Advertisement

SPECIFICATIONS............................
INTRODUCTION.............................
VENTING.......................................
GAS SUPPLY..................................
CLEARANCES................................
DRAFT DIVERTER..........................
DOOR KNOB.................................
PILOT ADJUSTMENT......................
These installation instructions are a general guide and do not supersede applicable local codes and ordinances. Before
planning or making the installation be sure it complies with all phases of the local heating code. (Or, in the absence of
local codes, with the latest edition of National Fuel Gas Code, ANSI.Z223.1, or CAN1-B149).
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the latest edition of National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code CSA-C22.1.
All of the ANSI and NFPA standards referred to in these installation instructions are the ones that were applicable at
the time the design of this appliance was certified. The ANSI standards are available from the American Gas Association,
1515 Wilson Blvd., Arlington, VA. 22209.
The NFPA standards are available from the national Fire Protection Association, 60 Batterymarch Street, Boston,
Massachusetts 02110.
Canadian standards are available from International Approval Services, 178 Rexdale Boulevard, Etobicoke, Ontario,
Canada M9W 1R3.
The design of this appliance was certified to comply with ANSI Z21.11.1 vented room heaters and CAN1-2.1-M86.
Installer must leave these instructions with the consumer, have them complete, and return the warranty card.
Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model Number is
correct and that the room heater is equipped for the type gas you intend to use.
TYPE
CONTROL
CLOSED FRONT THERMOSTAT BULB NATURAL
CLOSED FRONT THERMOSTAT BULB L.P.
RADIANT FRONT THERMOSTAT BULB NATURAL
RADIANT FRONT THERMOSTAT BULB L.P.
HEIGHT
DEPTH
INPUT (BTU/HR.)
GAS INLET/OUTLET SIZE
VENT SIZE
CENTER OF VENT TO FLOOR
NUMBER OF RADIANTS ("VCR" SERIES)
NUMBER OF RADIANT GLASS ("VCR" SERIES)
APPROX. SHIPPING WEIGHT ("VC" SERIES)
APPROX. SHIPPING WEIGHT ("VCR" SERIES)
*OPTIONAL BLOWER MODEL
*Blowers also available factory mounted on 50M Btu units. All 70M Btu units come with blower mounted only.

TABLE OF CONTENTS

2
3
3 ,4
5
5
6
7
7
7
8
READ CAREFULLY BEFORE INSTALLING UNIT
ROOM HEATER SPECIFICATIONS

SPECIFICATIONS

GAS
PROPER BURNER FLAME.......................... 9
MAINTENANCE..................................... 9
LIGHTING INSTRUCTIONS....................... 10
BLOWER INSTRUCTIONS..................
TSK WALL STAT KIT................................
PARTS DRAWING.............................
PARTS PRICE LIST............................
WARRANTY....................................
MODEL NUMBERS
VC201A-H VC351A-H
VC202A-H VC352A-H
N/A
VCR351A-H
N/A
VCR352A-H
20"
26"
24"
30"
15-1/4"
15-1/4"
20,000
35,000
1/2X3/8"
1/2X3/8"
3"
4"
16-1/2"
21-1/2"
N/A
5
N/A
2
55 LBS.
84 LBS.
N/A
96 LBS.
N/A
CHB-3
Page 2
VC501A-H
VC701A-H
VC502A-H
VC702A-H
VCR501A-H
VCR701A-H
VCR502A-H
VCR702A-H
26"
30"
30"
36"
19-1/4"
19-1/4"
50,000
70,000
1/2X3/8"
1/2X3/8"
4"
5"
21-1/2"
25-1/2"
5
5
2
2
112 LBS.
138 LBS.
124 LBS.
150 LBS.
CHB-3
CHB-3
8
11,12
13
14
15
16
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents