Configuring The Switch Through The Switch Browser-Based Interface - Lenovo Flex System EN2092 User Manual

1gb ethernet scalable switch
Hide thumbs Also See for Flex System EN2092:
Table of Contents

Advertisement

To log in to the switch, complete the following steps:
1. Connect one end of the specifically designed serial cable that comes with your
device into the mini-USB port and connect the other end to the management
station.
For additional information, see "Connecting the serial console cable" on page
10.
2. On the management station, open a console window and make sure that the
serial port is configured with the following settings:
v 9600 baud
v 8 data bits
v No parity
v 1 stop bit
v No flow control
3. Type the user name and password. The default user name is USERID. The
default password is PASSW0RD. The password is spelled with a zero, not the
letter O.
The serial port is compatible with the standard 16550 Universal Asynchronous
Receiver/Transmitter (UART) protocol. The mini-USB serial port is enabled by
default.
Configuring the switch through the switch browser-based
interface
Note: HTTP is disabled by default. HTTPS is not disabled by default.
Before you can access and start the browser-based interface, make sure that you
have completed the following procedures:
v Install the switch in the Flex System chassis.
v Make sure that the switch firmware is installed on the switch.
v Configure at least one IP interface on the switch.
v Enable frames and the JavaScript program in your Web browser.
The following hardware and software are required for the Web interface:
v A frame-capable Web-browser program, such as Internet Explorer (version 7.0 or
later), Mozilla Firefox (version 8.0 or later), or Google Chrome (version 16.0 or
later).
v A computer or workstation with network access to the switch
To start the browser-based interface, complete the following steps:
Chapter 2. Installing the switch