Sony DSR-250 Service Manual page 171

Hide thumbs Also See for DSR-250:
Table of Contents

Advertisement

1-2-2.
INITIALIZATION OF B PAGE DATA
Note: When reading the B page data, insert a "Memory Stick" into the
"Memory Stick" slot.
Switch setting:
MODE ................................................................... MEMORY
1. Initializing the B Page Data
Note: If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjustment Page
B
Adjustment Address
00 to FF
Initializing Method
Order Page Address Data
1
0
01
01
2
5
01
F3
3
5
00
01
4
5
01
5
5
00
6
5
02
7
Procedure
Set the data.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Wait for three seconds.
Check that the data is "00".
Check that the data is "00".
Perform "Modification of B
Page Data".
2. Modification of B Page Data
If the B page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Preparations:
Order Page Address Data
1
2
8F
2
2
8F
3
2
8F
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
1
2
00
2
2
01
3. B Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. or 3. Initializing the B
Page Data".)
Fixed data-2: Modified data. (Refer to "2. or 4. Modification of B
Page Data".)
Address
00 to 34
Fixed data-1
35
Fixed data-2
36,37
Fixed data-1
38
Fixed data-2
39
3A
3B
3C
3D
3E to 5F
Fixed data-1
60
Fixed data-2
61 to FF
Fixed data-1
5-13
Procedure
00
Set the data, and press PAUSE
button.
03
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
Procedure
29
Set the data.
29
Set the data, and press PAUSE
button.