INITIALIZATION OF A, B, C, D, E, F, 8 PAGE
DATA
1-2-1.
INITIALIZATION OF A, C, D, 8 PAGE DATA
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
D
Adjustment Address
10 to FF
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
A
Adjustment Address
00 to FF
1. Initializing the C, D, 8 Page Data
Note1: If "Initializing the C, D, 8 Page Data" is performed, all data of the
C page, D page and 8 page will be initialized. (It is impossible to
initialize a single page.)
Note2: If the C, D, 8 page data has been initialized, the following
adjustments need to be performed again.

1) Modification of C, D, 8 page data

2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) LCD system Adjustments
Initializing Method:
Order Page Address Data
1
0
01
01
2
3
81
3
3
80
0A
4
3
80
5
Procedure
Set the data
Check that the data is "00".
Set the data, and press the
PAUSE button.
Check that the data changes to
"1A"
Perform "Modification of C, D,
8 Page Data".
2. Modification of C, D, 8 Page Data
If the C, D, 8 page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, D, 8 Page data
Order Page Address Data
1
2
00
2
2
01
Note: If the following symptoms occur after completing of the
"Modification of C, D, 8 page data", check that the data of the "Fixed
data-2" addresses of D page are same as those of the same model of
the same destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is shut off so that unit cannot operate.
3. C Page Table
Note: Fixed data-1: Initialized data. (Refer to "1. Initializing the C, D, 8
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of C, D, 8
Page Data".)
Address
Initial value
00 to 0F
10
EE
11
00
12
00
13
00
14 to 15
16
E0
17
18
2A
19
2A
1A
1B
32
1C
32
1D
1E
25
1F
3E
20
3E
21
DC
22
99
5-9
Procedure
29
Set the data
29
Set the data, and press the
PAUSE button.
Remark
Switching position adj.
Fixed data-1
Cap FG duty adj.
Fixed data-1
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL f
adj.
0
APC adj.
LPF f
adj.
0

Hide quick links: