Power Up And Bind The Cs92 Transceiver; Wireless Cylinder Thermostat (Cs92) - Honeywell evohome Installation Manual

Hide thumbs Also See for evohome:
Table of Contents

Advertisement

16

Wireless Cylinder Thermostat (CS92)

evohome
Controller
If you are NOT
following GUIDED
CONFIGURATION
follow these steps
on your evohome
Controller display first:
1. Press and hold
"Settings"
for 3
seconds
2. Press the green tick
3. Select GUIDED
CONFIGURATION
4. Press STORED
HOT WATER
CONFIGURATION
5. Press the green tick
Step 3: Power up and bind devices
To control a stored hot water system you first need to bind
the CS92 Transceiver and then bind the Wireless Relay
Box (BDR91) that is controlling the hot water valve.

Power up and bind the CS92 Transceiver

On the CS92 Transceiver
Remove the CS92 Transceiver cover
1
Remove the battery tab and replace the cover
2
On the CS92 Transceiver press and hold the
3
button for 5 seconds. The green light should
come on and the red light should flash
Press the button again
4
You should receive a SUCCESS message on the
5
evohome Controller (if not go back and re-bind)
Choose the correct hot water valve type for the system
6
you're installing and follow the on screen instructions
1
3
1 2
PULL TAB
HOLD
5 SEC
PRESS
ONCE

Advertisement