Color Reproduction Adjustment (Nd Filter 1); Color Reproduction Adjustment (Nd Filter 2) - Sony DCR-VX2100 Adjustment Manual

Hide thumbs Also See for DCR-VX2100:
Table of Contents

Advertisement

DCR-VX2100/VX2100E

17. Color Reproduction Adjustment (ND Filter 1)

When the ND FILTER switch is "1", adjust the color difference
matrix coefficient so that proper color reproduction is produced.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: After the power is turned on, this adjustment can be done only once.
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) ND FILTER ........................................................................... 1
(The data of page: 6, address: 9D is "01".)
Adjusting method:
Order Page Address Data
1
2
0
01
3
F
5E
2D
4
E
62
5
E
63
6
E
64
7
E
65
8
6
01
9
6
01
10
6
02
11
12
Note3: The adjustment data will be automatically input to page: E, address:
62 to 65.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
02
3
F
5E
1D
3
0
01
Color bar chart
(Color bar standard picture frame)
Video output terminal
Vectorscope
E
62, 63, 64, 65
All color luminance points should
settle within each color reproduction
frame. (Fig. 6-1-11)
Procedure
Check that the picture frame is
set to the specified position.
(Refer to "8. Picture Frame
Setting".)
01
Set the data.
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
20
Set the data, and press PAUSE
button.
20
Set the data, and press PAUSE
button.
C3
Set the data, and press PAUSE
button.
C1
Set the data, and press PAUSE
button. (Note3)
Check that the data changes to
"01".
Adjust the GAIN and PHASE of
the vectorscope, and adjust the
burst luminance point to the
burst position of the color
reproduction frame. (Fig. 6-1-11)
Check that all color luminance
points settle within each color
reproduction frame. (Fig. 6-1-11)
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
Set the data, and press PAUSE
button.
00
Set the data.

18. Color Reproduction Adjustment (ND Filter 2)

When the ND FILTER switch is "2", adjust the color difference
matrix coefficient so that proper color reproduction is produced.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: After the power is turned on, this adjustment can be done only once.
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1) ND FILTER ........................................................................... 2
(The data of page: 6, address: 9D is "02".)
Adjusting method:
Order Page Address Data
1
2
0
01
3
F
5E
4
E
90
5
E
91
6
E
92
7
E
93
8
6
01
9
6
01
10
6
02
11
12
Note3: The adjustment data will be automatically input to page: E, address:
90 to 93.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
6
02
3
F
5E
4
0
01
5
6-24
Color bar chart
(Color bar standard picture frame)
Video output terminal
Vectorscope
E
90, 91, 92, 93
All color luminance points should
settle within each color reproduction
frame. (Fig. 6-1-11)
Procedure
Check that the picture frame is
set to the specified position.
(Refer to "8. Picture Frame
Setting".)
01
Set the data.
2D
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
00
Set the data, and press PAUSE
button.
20
Set the data, and press PAUSE
button.
20
Set the data, and press PAUSE
button.
CB
Set the data, and press PAUSE
button.
C9
Set the data, and press PAUSE
button. (Note3)
Check that the data changes to
"01".
Adjust the GAIN and PHASE of
the vectorscope, and adjust the
burst luminance point to the
burst position of the color
reproduction frame. (Fig. 6-1-11)
Check that all color luminance
points settle within each color
reproduction frame. (Fig. 6-1-11)
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
1D
Set the data, and press PAUSE
button.
00
Set the data.
Set ND FILTER switch to "OFF".

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-vx2100eRmt-811

Table of Contents