Download  Print this page

Alignment And Adjustments; High Voltage Transformer; Low Voltage Transformer - Samsung CK135 Service Manual

Hide thumbs

Advertisement

Table of Contents

5. Alignment and Adjustments

1. High voltage is present at the high voltage terminals during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the high voltage.
3. Before touching any oven components or w iring, alw ays unplug the oven from its pow er source and discharge the high voltage
capacitor.

5-1 High Voltage Transformer

1. Remove connectors from the transformer terminals
and check continuity.
2. Normal resistance readings are as follows:
Secondary
Filament
Primary
(Room temperature = 20˚C)

5-2 Low Voltage Transformer

1. The low voltage transformer is located on the
control circuit board.
2. Remove the low voltage transformer from the
PCB Ass'y and check continuity.
3. Normal resistor reading is shown in the table.
5-3 Magnetron
1. Continuity checks can indicate only an open
filament or a shorted magnetron. To diagnose an
open filament or shorted magnetron :
2. Isolate the magnetron from the circuit by
disconnecting its leads.
3. A continuity check across the magnetron filament
terminals should indicate one ohm or less.
4. A continuity check between each filament terminal
and magnetron case should read open.
Samsung Electronics
PRECAUTION
98.6 Ω ± 10%
Show s Continuity
1.44 Ω ± 10%
Primary
Terminals
Terminals
1~2(Input)
3~4(Output)
5~6(Output)
M agnetron Antenna
Cooling Fins
Filament Terminals
Resistance
290 Ω
4.0 Ω
1.0 Ω
Gasket Plate
5-1

Advertisement

Table of Contents
loading