Administration
LAN Settings
3.2.3

LLDP-MED Operation

OpenStage phones support LLDP-MED (Link Layer Discovery Protocol-Media Endpoint Dis-
covery) for auto-configuration and network management. The auto-configurable parameters
are VLAN ID (see Section 3.2.2, "VLAN") and Quality of Service parameters (see Section 3.3.1,
"Quality of Service (QoS)").
The data sent by a network device is stored in neighboring network devices in MIB (Manege-
ment Information Base) format. In order to keep this information up-to-date, a specific TTL
(Time To Live) is specified in LLDP. This value tells a device how long the received information
is valid. For OpenStage phones, the value range is 40, 60, 80, 100, 110, 120, 140, 180, 240,
320, 400.
An example for LLDP-MED operation an OpenStage phones can be found in Section 4.4, "An
LLDP-Med Example".