Manual Mode - Health Zenith SH-5512 Instruction Manual

Dualbrite twin halogen motion sensing light
Table of Contents

Advertisement

Available languages

Available languages

Mode Switching Summary
TEST
AUTO

MANUAL MODE

* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
INSTALLATION
CAUTION: Keep the sensor at least 1" (25 mm)
away from the bulbs.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the
fixture operate at high temperatures.
• Keep fixture at least 1" (25 mm) from combustible materi-
als. Do not aim at objects closer than 3 ft. (1 m).
• Use only T3, 150W (maximum) tungsten halogen 120
VAC bulbs.
For easy installation, select an existing light operated
by a wall switch for replacement. IMPORTANT: Do NOT
use with dimmers or timers.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE: If fixture is mounted
higher than 8 feet (2.4 m), aiming the sensor down will
reduce coverage distance.
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch
off for one second
then back on*
Timer
®
rite
Wall Mount
NOTE: Light fixture and sensor should be mounted as
shown above when installed (depending upon type of
installation).
Before installing the light fixture under an eave, the
sensor head must be rotated as shown in the next
two steps for proper operation and to avoid the risk of
electrical shock.
IMPORTANT: For proper under-eave operation, install
light shield (included). See Light Shield Installation
for details.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
Eave Mount
Controls
Controls
598-1160-05

Advertisement

Table of Contents
loading