IC2 VHiLC78636E-1: Servo/Signal Control (LC78636E) (2/2)
Terminal Name Input/Output Setting in Reset
Pin No.
44
LVDD
45
LCHO
46
LVSS
47
RVSS
48
RCHO
49
RVDD
50
XVDD
51
XIN
52
XOUT
53
XVSS
54
ASLRCK
55
ASDACK
56
ASDFIN
57*
LRSY
58*
DATACK
59*
DATA
60*
16M
61*
SFSY
62*
SBSY
63*
PW
64
SBCK
65
CE
66
CL
67
DI
68
DO
69
INT
70
WRQ
71
RES
72
DEF
73
VDD5V
74
VSS
75
CONT6
76
CONT7
77*
V/P
78*
FSEQ
79*
DEFECT
80*
EFMO
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Be sure to supply the same potential to each power terminal. (VVDD,ADAVDD,VDD,LVDD,RVDD,XVDD)
Terminal witch is controlled by the power terminal (VDD5V) for a microcomputer interface :
CE (65pin), CL (66pin), DI (67pin), DO (68pin), INT (69pin), WRQ (70pin), RES (71pin), DRF (72pin),
CONT6 (75pin), CONT7 (76pin)
Output
1/2VDD
Output
1/2VDD
Input
Oscillation
Output
Oscillation
Input
Input
Input
Output
L
Output
L
Output
L
Output
Clock output
Output
L
Output
L
Output
L
Input
Input
Input
Input
Output
L
Output
H
Output
H
Input
Output
L
In/Output
Input mode
In/Output
Input mode
Output
H
Output
L
In/Output
Input mode
Output
Unfixed
L channel
Power terminal for L channel.
D/A converter L channel output terminal.
Ground terminal for L channel. Surely connected to 0V.
R channel
Ground terminal for R channel. Surely connected to 0V.
D/A converter R channel output terminal.
Power terminal for R channel.
For quartz
Power terminal for quartz oscillation.
oscillation
Ground terminal of 16.9344MHz quartz oscillation.
Ground terminal for quartz oscillation. Surely connected to 0V.
For anti
L/R clock input terminal. (When not used,connect to 0V)
shock mode
Bit clock input terminal. (When not used,connect to 0V)
L/R channel data input terminal. (When not used,connect to 0V)
For digital
L/R clock output terminal.
data output
Bit clock output terminal.
L/R channel data output terminal.
16.9344MHz output terminal.
Output terminal of synchronous signal of subcode frame.
It drops when subcode stand by.
Output terminal of synchronous signal of subcode block.
Output terminal of subcodes P,A,R,S,T,U and W.
Clock input terminal to read subcode. (When not used,connect to 0V)
For
Chip enable signal input terminal.
microcomputer
Data transmission clock input terminal.
interface
Data input terminal.
Data output terminal.
Interruption signal output terminal.
Interruption signal output terminal.
Reset input terminal of LC78640. When turning on power, set it at "L".
Focus ON detection terminal.
Power terminal for microcomputer interface.
Ground terminal of digital system. Surely connected to 0V.
General purpose input/output terminal 6.
General purpose input/output terminal 7.
Monitor output terminal for automatic switch of rough servo/phase control.
"H" for rough servo, and "L" for phase servo.
Output terminal synchronous signal detection. "H" is output when synchronous signal
detected by EFM signal matches synchronous signal internally generated.
Defect terminal. After resetting, it is configured as an input terminal. It can be controlled
from the outside. It also becomes a defect monitor terminal under command control
EFM signal output terminal.
– 47 –
CD-BK1600V/1800V/190V
Function
Controlled with serial data command
from microcomputer. When not used,
set it as the input terminal and
open it by connecting to 0V, or set it
as the output terminal and open it.