318
NOTE
Do not remove the friction spring ( B,
Figure 11) unless a new spring will be
installed.
7. Remove the pawl (Figure 12) and pawl
spring (Figure 13).
8. Remove the sheave (Figure 14) and rope
assembly from the starter housing.
9. If the rope is being replaced, remove the rope
from the sheave.
WARNING
Be careful
if
the rewind spring has re-
mained in the cavity of the housing (Fig-
ure 15 ), because it may unwind suddenly
and violently, causing serious injury.
Wear safety glasses and gloves while
removing and installing the spring.
10. Place the rewind assembly housing on the
floor with the closed side up (Figure 16). Tap
lightly on the top of the housing while holding it
®