B-10
DUAL
PROCEDURE
CONTROL (K1449-1)
When this option is connected to the LN-10 Control
Box receptacle, and the Procedure Key selects
"REMOTE" the front panel knob controls and proce-
dure selection is transferred to the knob encoder con-
trols and Procedure Selector Switch of the remote,
which function in the exact same manner. Remote
knob encoders set Weld voltage and wire feed speed,
as well as Trigger Cold Feed Speed, but not Timers or
Run-In.
If using the optional K683-1, -3 Dual Procedure
Switch, for a wire drive, to select A or B along with the
(K1449-1) remote, both the front panel and remote
Procedure selector and switch must be set to
"REMOTE" and "Gun Switch" (center) positions.
The LN-10 Procedure lights indicate whether A or B is
remotely selected.
WIRE REEL LOADING - READI-REELS,
SPOOLS OR COILS
To Mount a 30 Lb. (14 kg) Readi-Reel Package
(Using the Molded Plastic K363-P Readi-Reel
Adapter:)
The Spindle should be located in the LOWER mounting hole.
1) Depress the Release Bar on the Retaining Collar
and remove it from the spindle.
2) Place the Adapter on the spindle.
3) Re-install the Retaining Collar. Make sure that the
Release Bar "pops up" and that the collar retainers
fully engage the retaining groove on the spindle.
4) Rotate the spindle and adapter so the retaining
spring is at the 12 o'clock position.
5) Position the Readi-Reel so that it will rotate in a
direction when feeding so as to be de-reeled from
bottom of the coil.
6) Set one of the Readi-Reel inside cage wires on the
slot in the retaining spring tab.
7) Lower the Readi-Reel to depress the retaining
spring and align the other inside cage wires with
the grooves in the molded adapter.
8) Slide cage all the way onto the adapter until the
retaining spring "pops up" fully.
OPERATION
REMOTE
Check to be sure the Retaining Spring has fully
returned to the locking position and has SECURELY
locked the Readi-Reel Cage in place. Retaining
Spring must rest on the cage, not the welding elec-
trode.
___________________________________________
9) To remove Readi-Reel from Adapter, depress
retaining spring tab with thumb while pulling the
Readi-Reel cage from the molded adapter with
both hands. Do not remove adapter from spindle.
To Mount 10 to 44 Lb. (4.5-20 kg) Spools
(12"/300 mm Diameter) or 14Lb.(6 Kg)
Innershield Coils:
The Spindle should be located in the LOWER mounting hole.
(For 8" (200 mm) spools, a K468 spindle adapter must
first be slipped onto spindle.)
(For 13-14 lb. (6 Kg) Innershield coils, a K435 Coil
Adapter must be used).
1) Depress the Release Bar on the Retaining Collar
and remove it from the spindle.
2) Place the spool on the spindle making certain the
spindle brake pin enters one of the holes in the
back side of the spool. Be certain the wire comes
off the reel in a direction so as to de-reel from the
bottom of the coil.
3) Re-install the Retaining Collar. Make sure that the
Release Bar "pops up" and that the collar retainers
fully engage the retaining groove on the spindle.
LN-10
WARNING
FIGURE B.1
B-10