Minimum Limits Setting Mode Selection

The LN-10 control is set up for allowing a minimum weld
WFS and arc voltage setting for each procedure by set-
ting S2 DIP Switch 6 (Labeled "-").
S2 switch 6 ON - Minimum Limits Setting mode ON
M 4 S R + -
ON
1
2
3
4
S2
When Minimum Limits Setting mode is selected, all keys
except the procedure key are disabled. Welding is not
allowed while in this mode. The mode is used for mini-
mum limits setup only. See "Limits Setting Mode" in this
section for the correct procedure for setting the WFS and
voltage limits.
S2 switch 6 OFF = Minimum Limits Setting mode OFF
(As shipped)
M 4 S R + -
ON
1
2
3
4
S2