Installation; Technical Specifications - Lincoln Electric IDEALARC CV-250 Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS – IDEALARC CV-250
Standard
Voltage
208/230/460/3/60
230/460/575/3/60
Duty Cycle
100% Duty Cycle
NEMA Class I (100)
60% Duty Cycle
100% Duty Cycle
Welding Current/Voltage Range
(Continuous)
30A/7V - 300A/32V
DC
Efficiency at 100% Load
72%
Idle Power
800W
Height
21.5 in.
546 mm

INSTALLATION

INPUT - THREE PHASE ONLY
Input Current at
Rated Output
100% Duty Cycle 56/51/26
60% Duty Cycle 62/56/28
100% Duty Cycle 51/26/20
60% Duty Cycle 56/28/22
RATED OUTPUT
Amps
250
300
250
OUTPUT
Normal Open Circuit Voltage
10-43
MAX OCV: 50
MISC. INFORMATION
Input kVA
60% Load - 22.3
100% Load - 20.3
Power Factor at 100% Load
.53
PHYSICAL DIMENSIONS
Width
19.5 in.
(Lift bail, add 3.12 in)
495 mm
(Lift bail, add 80 mm)
CV-250
Code
Number
10013
10014
Volts at Rated Amperes
30
32
30
Auxiliary Power
42 Volts AC, 10 Amps
115 Volts AC, 5 Amps
( Both Circuit Breaker Protected)
Idle Current - Amps
11/10/5
Depth
Weight
27.0 in.
300 lbs
(137 kg)
686 mm
A-1

Hide quick links:

Advertisement

Table of Contents
loading