Olp(Overload Protector); To Remove The Cover Ptc - Kenmore 795.78502800 Service Manual

Hide thumbs Also See for 795.78502800:
Table of Contents

Advertisement

4-3 OLP (OVERLOAD PROTECTOR)
4-5-1 Definition of OLP
(1) OLP (OVERLOAD PROTECTOR) is attached to the
Compressor and protects the Motor by opening the
circuit to the Motor if the temperature rises and
activating the bimetal spring in the OLP.
(2) When high current flows to the Compressor motor, the
Bimetal works by heating the heater inside the OLP,
and the OLP protects the Motor by cutting off the
current flowing to the Compressor Motor.
4-5-2 Role of the OLP
(1) The OLP is attached to the Sealed Compressor used
for the Refrigerator. It prevents the Motor Coil from
being started in the Compressor.
(2) For normal operation of the OLP, do not turn the Adjust
Screw of the OLP in any way.
(OVERLOAD PROTECTOR
cross section)
Customer part
number
12345678
Lot code/
date code
330 FBYY
-S1 BOX98
Electrical
Physical
characteristics
termination
part number
part number
Part
No.
Name
Base, phenolic
(UL 94 V-0 rated)
Movable arm support, plated steel
Stationary contact support,
plated steel
Heater support, plated steel
Heater, resistance alloy
Disc, thermostatic alloy
Movable arm, spring temper
copper alloy
Contact, movable, silver on copper
Contact, stationary, silver on copper
Slug, plated steel
Cover, polyester
(UL 94 V -0 rated)
Pin connector, plated copper alloy
(To engage 2.33/2.66 mm dia. pin)
Quick-connect terminal, brass,
conforms to UL 310, MEMA
DC-2, DIN 46344
Figure 19
- 19 -

4-4 TO REMOVE THE COVER PTC

(1) Remove the Cover Back M/C.
(2) Disconnect two housing upper side of comp connected
in.
(3) Loosen two screws on comp base.
1
(4) Use a L-shaped flap tool to pry off the cover.
(5) Assembly in reverse order of disassembly.