  • Page 1 Komet 19 Owner’s Manual  Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 2 Excessive heat can only cause this tolex situation and this is not covered under your Komet warranty.  Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 3: Front Control Panel Layout

    This procedure will prolong the lifespan of the amplifier’s tubes. 8. Power Switch: engages the AC wall power to the amplifier. Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 4 - as to not accidentally entangle the wire retainers. ( continued ) Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 5 V2 phase inverter socket where microphonics are not as noticeable. The V2 position 12AX7 may be quieter in the V1 position. ( continued ) Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 6 19 is an IP number range from # 12 through # 16. Groove  Tube's scale for the K 19 is a grade # 1 or # 2. Note: the 12AX7 pre amp tubes in your amplifier are internally self biased and need no adjustment.
  • Page 7: Troubleshooting

    ( 1 Amp slow blow 240V ) on ( with no power tubes in the sockets ). ( continued ) Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 8 This would require that the inside of the input jack be cleaned professionally. We recommend using DeoxIT GOLD G5. ® ( continued ) Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 9 If not replaced, they will fail and “ short out “ in short order, and the ( IP ) H.T. fuse will blow. Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 10 19 COMBO  The K 19 combo, as with any back panel mount combo, will be prone to microphonic pre amp tube problems over time. This is due to the construction and nature of the amplifier mounting. We recommend, when replacing tubes, purchasing pre-tested ( for microphonics ) amp tubes from a reputable tube dealer.
  • Page 11 Repeat procedure always from the center. Avoid using T-shirts or cloths that contain graphics or embroidery. They may scratch some surfaces of your amp. Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 12: A Final Word

    Have fun! Thank you for purchasing our product. Michael Kennedy Holger Notzel Co-owners Komet Amplification  Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 13 Gene Sinigalliano ( 212 ) 967-5626 email: ultrasound@ultrasoundrehearsal.com Ken Volpe ( 203 ) 966-2096 email: kengit@optonline.net Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 14 ALWAYS insure your amplifier for the full value of the amplifier. ( at the very least ) Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification.
  • Page 15 Excessive heat can only cause this tolex situation and this is not covered under your Komet warrant  Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. KometAmplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. KometAmplification...
  • Page 16 Note: Komet Amplification recommends using a 16 Ohm load with their amplifiers for the best sonic results. Copyright 2000-2012, Riverfront Music, L.L.C. d.b.a. Komet Amplification. May not be reproduced in any form without express written consent from Riverfront Music, L.L.C. d.b.a. Komet Amplification.