Adjustment - Kenwood DP-4090 Service Manual

Compact disc player
Hide thumbs Also See for DP-4090:
Table of Contents

Advertisement

No.
ITEM
Step 1~4 are in TEST MODE
1
LASER POWER
TRACKING ERROR
2
BALANCE
FOCUS ERROR
3
BALANCE
4
TRACKING GAIN
Note:
Type 4 disc : SONY YEDS-18 Test Disc or equivalent.
LPF: Around 47 kΩ+ 390 pF or so.
(a) Laser power
Pickup

ADJUSTMENT

INPUT
OUTPUT
SETTINGS
SETTINGS
Apply the sensor section
of optical power meter
on the pickup lens.
Connect an oscilloscope
Test disc
as follows.
Type 4
CH1 : RF (CN2 pin 1)
CH2 : TE (CN2 pin 6)
Connect an oscilloscope
Test disc
as follows.
Type 4
CH1 : RF (CN2 pin 1)
CH2 : FE (CN2 pin 2)
Test disc
Connect a LPF to CN2
Type 4
Apply signal of
pin 5-6 to which you
1.2 kHz,
connect an oscilloscope
50mVrms to
or AC voltmeters.
CN2 pin 5-6.
0.08~0.15 mW
Optical power meter
DP-4090/5090/D-S300
PLAYER
ALIGNMENT
SETTINGS
POINTS
While pressing the
UP key, turn the AC
ON. (Test mode)
Press the
PLAY/PAUSE key,
then confirm that the
display is "03".
Press the
PLAY/PAUSE key,
TE BALANCE
then confirm that the
VR2
display is "03".
Press the
PLAY/PAUSE key,
FE BALANCE
then confirm that the
VR1
display is "05".
Press the
TRACKING
PLAY/PAUSE key,
GAIN
then confirm that the
VR3
display is "05".
(e) Tracking gain
CN2
1
2
3
_
4
1.2 kHz
5
50 mVrms
6
+
7
ALIGN
FOR
On the power from
0.08 to 0.15 mW,
when the diffraction
grating is correctly
aligned with the RF
level of 1.0 Vp-p or
more.
Symmetry between
upper and lower pat-
terns
Optimum eye pattern
Two VTVMs should
read the same value.
GND
+
L.P.F.
VTVM
+
L.P.F.
VTVM
FIG.
(a)
(e)
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-5090D-s300

Table of Contents