Basic Adjustment; Power Adjustment; Rssi Control - Mitsubishi Electric TRIUM 110 Service Manual

Hide thumbs Also See for TRIUM 110:
Table of Contents

Advertisement

4.2 Basic Adjustment

1
Use MT Tools 2000
(Vers.103 Ed.02 or higher) to set all the parameters.

4.2.1 Power Adjustment

Each mobile is adjusted in the factory and the TX parameters (Power Control Level values and ramping values)
are stored in the Flash Data (IC202)
About the adjustment value of TX Power, see the following table.
E-GSM
Ch-62
Power Level
PCL
(dBm)
33
5
31
6
29
7
27
8
25
9
10
23
11
21
12
19
13
17
14
15
15
13
11
16
9
17
7
18
5
19

4.2.2 RSSI control.

Set your radiocommunication tester at a given reference and check RSSI :
1
See Manual FA9M0640
Version A
Date: 05/02
10/22
tolerance
+/-2dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-5dB
+/-5dB
+/-5dB
+/-5dB
REF Gene
-83.5 dBm
-60.5 dBm
+:
Z.A. Pigeon Blanc, 35 370 St Germain du Pinel France
( :
FAX:
DCS
Ch-698
Power Level
PCL
(dBm)
30
0
28
1
26
2
24
3
22
4
5
20
6
18
7
16
8
14
9
12
10
10
8
11
6
12
4
13
2
14
0
15
RSSI
27 +/- 4
50 +/- 4
Mitsubishi Electric Telecom Europe S.A.
After Sales Services
+33 (0)2 23 55 16 30
+33 (0)2 99 75 71 62
Service Manual
Trium 110
tolerance
+/-2dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-3dB
+/-4dB
+/-4dB
+/-4dB
+/-4dB
+/-4dB
+/-5dB
+/-5dB

Advertisement