Connection Maintenance Interval; Considerations - Motorola DS6878 Product Reference Manual

Hide thumbs Also See for DS6878:
Table of Contents

Advertisement

Connection Maintenance Interval

NOTE The Connection Maintenance Interval only applies in locked pairing mode (see
When a digital scanner disconnects from a cradle due to a Link Supervision Timeout, the digital scanner
immediately attempts to reconnect to the cradle for 30 seconds. If the auto-reconnect process fails, it can be
restarted by pulling the digital scanner trigger.
To guarantee that a disconnected digital scanner can reconnect when it comes back in range, the cradle reserves
the connection for that digital scanner for a period of time defined by the Connection Maintenance Interval. If the
cradle is supporting the maximum three digital scanners and one digital scanner disconnects, a fourth digital
scanner cannot pair to the cradle during this interval. To connect another digital scanner: either wait until the
connection maintenance interval expires then scan the PAIR bar code on the cradle with the new digital scanner;
or, scan Lock Override
NOTE When the CR0078-S cradle supports the maximum three digital scanners and the CR0078-P supports the
maximum seven digital scanners, it stores the remote pairing address of each digital scanner in memory
regardless of the digital scanner condition (e.g., discharged battery). When you want to change the digital
scanners paired to the cradle, unpair each digital scanner currently connected to the cradle by scanning
the
Unpairing
code on the cradle.
Connection Maintenance Interval options are:
15 minutes
30 minutes
One hour
Two hours
Four hours
Eight hours
24 hours
Indefinitely.

Considerations

The system administrator determines the Connection Maintenance Interval. A shorter interval allows new users to
gain access to abandoned connections more quickly, but causes problems if users leave the work area for
extended periods. A longer interval allows existing users to leave the work area for longer periods of time, but ties
up the system for new users.
To avoid this conflict, users who are going off-shift can scan the unpair bar code on
Connection Maintenance Interval and make the connection immediately available.
(page
4-20) with the new digital scanner then scan the PAIR bar code on the cradle.
bar code prior and reconnect each appropriate digital scanner by scanning the PAIR bar
Radio Communications 4 - 23
page
4-20).
page 4-21
to ignore the