Download  Print this page

Service Information; Troubleshooting; Charging System - KYMCO ZX/SCOUT 50 Service Manual

Hide thumbs

Advertisement

Table of Contents
15
. ELECTRICAL EQUIPMENT

SERVICE INFORMATION

GENERAL INSTRUCTIONS
• It is not necessary to check the battery electrolyte or fill with distilled water.
• Remove the battery from the motorcycle for charging.
• Do not quick charge the battery.
• Charge the battery according to the charging current and time specified on the battery.
• When charging, check the voltage (open voltage) with an electric tester.
• When replacing the battery, do not use a traditional battery.
SPECIFICATIONS
Battery
Spark plug
Spark plug gap
Ignition coil resistance
Pulser coil resistance (20 )
Ignition timing

TROUBLESHOOTING

CHARGING SYSTEM

No power
• Dead battery
• Disconnected battery cable
• Fuse burned out
• Faulty ignition switch
Low power
• Weak battery
• Loose battery connection
• Charging system failure
• Faulty regulator/rectifier
15-1
Quick charging should only be done in an emergency..
Capacity
Voltage
Charging Standard
current
Quick
(NGK)
Primary coil
Secondary coil
(with plug cap)
Secondary coil
(without plug cap)
Do not remove the electrolyte cap..
SC10AS
12V3AH
13.0 13.2V
0.4A/10H
4A/0.5H
BR8HSA
0.6 0.7mm
0.153 0.187Ω
6.99 10.21KΩ
3.24 3.96KΩ
80 160Ω
15.5°±2°BTDC/2000rpm
Intermittent power
• Loose battery cable connection
• Loose charging system connection
• Loose connection or short circuit in ignition system
• Loose connection or short circuit in lighting system
Charging system failure
• Loose, broken or shorted wire or connector
• Faulty regulator/rectifier
• Faulty A.C. generator