INSTALLATION
Continued
We recommend that you install a sediment trap in
supply line as shown in Figure 4. Locate sediment
trap where it is within reach for cleaning. Install
in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not
likely to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going into log
set controls. If sediment trap is not installed or is
installed wrong, log set may not run properly.
Approved Flexible Gas Hose
(if allowed by local codes)
3" Minimum
Cap
Sediment Trap
Figure 4 - Gas Connection
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 19.
** Minimum inlet pressure for purpose of input
adjustment.
8
CSA Design-
Certified Equipment
Shutoff Valve With
1/8" NPT Tap*
From Gas
Meter (5"
W.C.** to
10.5" W.C.
Pressure)
Pipe
Tee
Nipple
Joint
www.desatech.com