Chapter 7: Server
Monitoring
Confirming HD VISUAL
COMMUNICATION SERVER Status
The status of the HD VISUAL COMMUNICATION SERVER can be
confirmed by either displaying processes or referencing log files.
How to Display Processes
1
Right-click on the Server Desktop and click on [Open Terminal] from the
menu.OLM
2
When the Terminal Software opens, execute the following command.
# /usr/local/vn/bin/vnstatus
Under normal conditions, you will see the following results displayed:
cnode_mcu (pid 3870) is running...
beam (pid 3785 3766) is running...
vnncs (pid 3797) is running...
vnproxy (pid 3822 3810) is running...
vnutil (pid 3823) is running...
vnlmsvr (pid 3842) is running...
vnbms (pid 3863) is running...
vnpms (pid 3885) is running...
vngk (pid 3901) is running...
vnmcu (pid 3917) is running...
vnvnc (pid 3932) is running...
vnapi (pid 3945) is running...
How to Reference the Log File of Meeting Server
1
Right-click on the Server Desktop and click on [Open Terminal] from the
menu.
2
The Terminal Software will open so execute the following command.
cp -r /var/log/ /[Log File Save Destination]/