TRBL
ANLS

SELF-DIAGNOSIS

9010
9020
R/B
L/W
9030
SELF-DIAGNOSIS

DIAGNOSIS CODE INDICATION

1. Normal condition
(no defective part or irregular process-
ing is found)
Single flash is given every 4.95 seconds.
a : Light on, 0.33 second
b : Light off, 4.95 seconds
2. Trouble code indication
Example: The illustration indicates code
number 23.
a : Light on, 0.33 second
b : Light off, 0.33 second
c : Light off, 1.65 seconds
d : Light off, 4.95 seconds
DIAGNOSIS THE ELECTRONIC
CONTROL SYSTEM
1. Install:
• Diagnostic indicator
Warning lamp
6Y5-83536-10 (socket)
6Y5-83517-00 (valve)
NOTE:
When performing this diagnosis, all of the
electrical wires must be properly con-
nected.
2. Check:
• Diagnosis code
Code 1 is indicated → Normal.
Code 13 - 29 indicated → Check the
applicable parts.
Code 33 - 44 indicated → Replace the
CDI unit.
9-5