Download Print this page

Frigidaire FGEW2765K F Installation Manual page 8

Single wall ovens 27" electric
Hide thumbs Also See for FGEW2765K F:

Advertisement

(excludes side swing wall oven)
30"/ 27" Electric Single Wall Oven
Under-Counter Installation Specifications
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
Always consult local and national electric codes.
Minimum 21" clearance for oven door depth when open.
Minimum 23-1/2" deep cutout dimension is critical for proper
installation, to ensure that oven's faceplate will fit flush against
cabinet front.
Side filler panels necessary to isolate oven from adjoining cabinets.
Full oven base of solid plywood or similar material required, capable
of supporting 200 Lbs. (30" models) or 150 Lbs. (27" models).
Install over two runners and flush with toe plate.
Base must be level and cabinet front must be square.
Allow 5" maximum height from oven base to floor, if NO cooktop is
installed directly over wall oven.
USA
10200 David Taylor Drive
Charlotte, NC 28262
CANADA
5855 Terry Fox Way
EC_EW INST FR 02/12
Over 30"/27" Electric Single Wall Oven
1-800-FRIGIDAIRE
Mississauga, ON L5V 3E4
1-800-265-8352
Electric Cooktop Installation
Electric Cooktop Installation Over
30"/ 27" Electric Single Wall Oven Specifications
All Frigidaire® Electric Single Wall Ovens are approved to be used
beneath any approved Frigidaire® Electric Cooktop. (This installation
page excludes approved wall oven model GLEB27Z7H. For model-
specific installation details, refer to Electric Cooktop Installation Over
27" Electric Single Wall Oven GLEB27Z7H Specifications pages on web.)
For detailed Electric Cooktop installation, refer to model-specific
product page and installation guide on web.
Side filler panel height may need to be modified to accommodate the
depth of approved electric cooktop models.
To route armored cable to junction box, cut minimum 4" x 4" opening
in right side filler panel.
Allow 4-1/2" maximum height from oven base to floor, if cooktop is
installed directly over wall oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
frigidaire.com
frigidaire.ca
© 2012 Electrolux Home Products, Inc.
Specifications
subject to change.

Advertisement