MODEL VC5000 DIGITAL
DAY/NIGHT COLOR CAMERA
©
Copyright
2002 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: +44 (0) 1489-566300 INFOFAX: 800-287-1207 WEB www.vicon-cctv.com
Vicon part number 8009-8119-00-01 Section 1 Rev 702

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VC5000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon VC5000

  • Page 1 2002 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered trademarks of Vicon Industries Inc. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: +44 (0) 1489-566300 INFOFAX: 800-287-1207 WEB www.vicon-cctv.com...
  • Page 2: Table Of Contents

    Depending on the conditions of use, installation and environment, FEATURES please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer. • The optical filter is switched automatically to color image or black CONTENTS and white image according to the subject brightness.
  • Page 3: Information To User

    (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Vicon may This installation should be made by a qualified service person and void the user’s authority to operate this camera.
  • Page 4: Shipping Instructions

    SHIPPING INSTRUCTIONS Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 5: Precautions

    Do not open the cabinet, as it may be dangerous and cause damage as spotlights, etc., or where it could be subject to direct sunlight, as to the unit. For internal settings and repairs, contact Vicon Technical that could cause deformation, discoloration or other damages.
  • Page 6: Parts Names

    PARTS NAMES Lens iris output connector (4 pin) This 4-pin connector is used to send the DC control signal and power supply to an auto-iris type lens. Flange-back adjustment lever (See page 8) Flange-back lock screw Lens mount cap The cap is installed to protect the lens mount section. Remove the lens mount cap before installing a lens (sold separately).
  • Page 7 PARTS NAMES Camera setup section (under the cover) This unit factory settings are as indicated below. These settings are for when using a 1/3 inch CS mount DC (without EE internal amplifier) type lens. However, if due to installation conditions or environment the settings may need to be modified for best results (see "SETTINGS").
  • Page 8 PARTS NAMES Power indicator (POWER) Comes on when the power to the camera is on. Video output connector (VIDEO OUT: BNC type) Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector. Line phase adjustment volume (LINE PHASE) When using two cameras or more, the image on the monitor may roll vertically when switching sources.
  • Page 9 PARTS NAMES Flange-back adjustment If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the flange-back position as described below.
  • Page 10: Mounting The Lens

    MOUNTING THE LENS Check the lens mount Do not use a lens if the length “ ” is more than mm. That may damage the camera and prevent proper installation. Installation of a DC type auto-iris lens (sold separately) A 1/3 inch CS mount type lens without EE amplifier circuit that only uses a DC power source. This camera can receive (the A.I.
  • Page 11 MOUNTING THE LENS Set the A.I. LENS switch in the camera setup section to the VIDEO position. Pin layout VIDEO DC type lenses VIDEO type lenses Brake coil (–) +12 V DC (50 mA max.) Brake coil (+) Not used Drive coil (+) Video output (1.0 Vp-p, high impedance) Drive coil (–)
  • Page 12: Connections

    CONNECTIONS Basic connection for monitoring or recording The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately. Make the video signal connection between the camera and the monitor or time lapse VCR. Insert the plug of this power cord into a wall outlet. The POWER indicator (A) will light.
  • Page 13: Settings

    SETTINGS C-BW VR301 LEVEL SYNC VIDEO A. I. VR303 VR302 LENS Line phase adjustment CAUTION: If the vertical roll cannot be corrected by setting the LINE PHASE When using a camera switcher to connect 2 cameras or more to one volume on camera 2, try setting the LINE PHASE volume on camera monitor, there may be a vertical roll of the images when switched.
  • Page 14: Backlight Compensation Setting

    SETTINGS Lens iris adjustment Backlight compensation setting If using a DC type auto-iris lens, you will need to set the LEVEL Use an auto-iris lens and set the EI/BLC switch to the BLC-ON (VR301) volume when shooting in the conditions described below. position, to engage the backlight compensation function.
  • Page 15 SETTINGS Electronic iris function setting Use a manual or fixed iris lens and set the lens aperture to the When using an auto-iris lens (for indoor/outdoor shortest F stop. Set the EI/BLC switch to the EI-ON position. use) Set the EI/BLC switch to the OFF position. CAUTION: If conditions are outside the electronic iris operation range or more than the maximum illumination, it will cause saturation of the CCD.
  • Page 16 SETTINGS C • • • • B/W (color/black and white) switch setting This switch lets you select the timing of the automatic switching of the optical filter to color image or black and white image, according to the subject brightness. The default setting is “L”. Set the switch according to the brightness.
  • Page 17: Troubleshooting

    TROUBLESHOOTING Before taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform correctly, contact Vicon. See Shipping Instructions on page 3. No picture on the monitor screen •...
  • Page 18: Specifications

    However, in the event of a White balance : ATW/Manual switching problem, the owner is advised not to attempt to make repairs or open Lens mount : CS mount the cabinet. Contact Vicon if you need service. See Shipping Instructions on page 3. English...
  • Page 19 Software supplied either separately or in hardware is furnished on an "As Is" basis. Vicon does not warrant that such software shall be error free and if errors do occur, Vicon’s only obligation shall be to exercise due diligence in working to correct such errors.
  • Page 20 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Infofax: 800-287-1207 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom 44/(0) 1489/566300 Fax: 44/(0) 1489/566322 Brussels Office Planet II - Unit E...