LG WM3885H*CA Service Manual page 30

Hide thumbs Also See for WM3885H*CA:
Table of Contents

Advertisement

HEATING ERROR
Is
displayed?
tE ERROR
Yes
Is the connector connected to
heater disconnected or
disassembled?
Steam generator heater
Wash heater
No
Is Check heater
resistance out of range?
(12~18 Ω)
(Refer to 9-6 Heater
assembly.)
No
Reconnect or
repair
Yes
the connector.
Replace the
HEATER
Yes
ASSEMBLY.
Is the connector connected to
thermistor disconnected or
disassembled?
Steam generator thermistor
Wash thermistor
No
Is thermistor resistance
out of range?
(about 39.5 kΩ at 30
(Refer to 9-7 thermistor
assembly.)
No
Check the trans of water
infiltration into thermistor
terminal.
- Does the water infiltrate
thermistor terminal?
[Note]
Chances that the cause occurs from the
main controller are very little.
Sensing part of the circuit (tE) consists of
only resistors and capacitors.
29
Reconnect or
Yes
repair
the connector.
Replace the
Yes
THERMISTOR
ASSEMBLY.
°C
)
Replace the
Yes
THERMISTOR
ASSEMBLY.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wm3875h*caLswf3885hvs

Table of Contents