40010, 40050
for DIN rail mounting
working description
The central module must be connected to a power supply unit (EGi ref. 40710,
40720 or 40730) that provides the needed power for proper function of the
system.
These units have been designed to distribute stereo audio from an audio source
(MP3, CD player, radio...) to the DOMOS2 installation.
before starting
Once the DOMOS2 system has been correctly installed, the different modules
must be configured for proper performance whitin the system. Each room is
called a ZONE.
This procedure will assign a zone to each control unit, so that the central unit
will detect and assign functions to each control unit, and intercomm will be set.
To reset or change the configuration on a system using the central unit
module EGi ref. 40050 or 40010, the control unit configuration manual
must be checked.
AUDIO
The central unit provides 1 (40010) or 3 (40050) RCA audio inputs (input
A, input B, input C), where a music source (walkman®, sound system, MP3...)
can be connected.
The central unit provides audio to the installation. To correctly listen the audio
provided by this unit, please refer to the control unit manual.
central units
ACOUSTIC SURVEILLANCE
This function does not need any interaction from the user in this module. Please refer to the control unit
manual for detailed working instructions.
DOOR ENTRY PHONE
This function does not need any interaction from the user in this module. Please refer to the control unit
manual for detailed working instructions.
CLOCK
This function does not need any interaction from the user in this module. Please refer to the control unit
manual for detailed working instructions.
MESSAGE RECORDER
This function does not need any interaction from the user in this module. Please refer to the control unit
manual for detailed working instructions.
Message recording is allowed when using control units EGi ref. 40250, 40260, 40270 and 40280. Please
refer to the control unit manual for details.
SOS
This function alerts about a dangerous situation or someone in need of help. The system generates an audio
signal in the zone where the alarm is generated. If not cancelled, the alarm spreads to the rest of the installation
for 2 minutes.
BELL
The unit manages the bell function by connecting the door entry bell to the central unit (6).