Signal Contacts - Canon BJC-55 Service Bulletin

Hide thumbs Also See for BJC-55:
Table of Contents

Advertisement

BJC-50

6.3 Signal Contacts

The scanner cartridge is recognized by TOP.S, DIAS and CCHK signals. The scanned
image output to the printer is transmitted with a SCLOCK signal in sync with a SDATA
signal.
The scanner is controlled by the internal register setting signals, CMD0, 1, 2 and 3.
TABLE 4-6 LIST OF SCANNER CARTRIDGE SIGNAL CONTACTS
No.
Signal
1, 2
LAMP G
5, 6
V LAMP
9
TOP. S
10
C. CHA
11
ID0
12
ID1
13
INKS 2
14
Vss
19
COM 0 (REN)
20
COM 1 (RWR)
21
COM 2 (RDT)
22
COM 3 (N.C)
23
Vdd
24
S CLOCK (DTCK)
25
S SYNE (LNST)
26
S RES
28
S DATA (DT)
29
C. CHK
Scanner Cartridge
Figure 4-35 Contact Pad Layout
Type
...
GND for LED
IN
LED drive voltage (+24Vdc)
OUT
Scanner detection GND
OUT
Scanner detection OPEN
OUT
Color scanner cartridge
acknowledge signal
OUT
Color scanner cartridge
acknowledge signal
OUT
IS-11/IS-12 detection
GND
GND
IN
Register enable
IN
Register write clock signal
IN
Register data signal
...
Not used
...
IC driver voltage (+5Vdc)
OUT
Scan data transfer signal
IN
Line start signal
IN
System reset signal
OUT
Scan data
OUT
HScanner detection OPEN
28
29
24
26
25
23
21
22
20
27
18
17
19
16
15
11 12 13 14
3
10
9
8
7
4 6 5
2 1
Description
4-49
Part 4: Technical Reference
(Ref. BJ Cartridge)
VHG
HVH
TOP
DIODEA
ID0
ID1
HVss
Odd ENB
BENB1
BENB2
BENB3
HVdd
HCLK
HLATCH
HRES
HDATA
DIODEK

Advertisement

Table of Contents
loading

Table of Contents