Manufactured Or Mobile Home Installation - Electrolux EIMED55IMB Installation Instructions Manual

Front-load gas & electric dryer
Hide thumbs Also See for EIMED55IMB:
Table of Contents

Advertisement

Exhaust system requirements, continued
WARNING
EXPLOSION HAZARD
Do not install the dryer where gasoline or other
fl ammables are kept or stored. If the dryer is
installed in a garage, it must be a minimum of 18
inches (45.7 cm) above the fl oor. Failure to do so
can result in death, explosion, fi re or burns.
In installations where the exhaust system is not
described in the charts, the following method must
be used to determine if the exhaust system is
acceptable:
1. Connect an inclined or digital manometer
between the dryer and the point the exhaust
connects to the dryer.
2. Set the dryer timer and temperature to air fl uff
(cool down) and start the dryer.
3. Read the measurement on the manometer.
4. The system back pressure MUST NOT be
higher than 1.0 inch of water column. If the
system back pressure is less than 1.0 inch of
water column, the system is acceptable. If the
manometer reading is higher than 1.0 inch of
water column, the system is too restrictive and
the installation is unacceptable.

Manufactured or mobile home installation

1.
Installation MUST conform to current
Manufactured Home Construction & Safety
Standard, Title 24 CFR, Part 32-80 (formerly the
Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or Standard
CAN/CSAZ240 MH.
2.
Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting
that will not support combustion. Metal ducting
must be 4 inches (10.16 cm) in diameter with no
obstructions. Rigid metal duct is preferred.
3.
If dryer is exhausted through the fl oor and
area beneath the mobile home is enclosed,
Installation Requirements
Install male fi ttings in correct direction:
CORRECT
Although vertical orientation of the exhaust system
is acceptable, certain extenuating circumstances
could affect the performance of the dryer:
Only the rigid metal duct work should be used.
Venting vertically through a roof may expose
the exhaust system to down drafts causing an
increase in vent restriction.
Running the exhaust system through an
uninsulated area may cause condensation and
faster accumulation of lint.
Compression or crimping of the exhaust system
will cause an increase in vent restriction.
The exhaust system should be inspected and
cleaned a minimum of every 18 months with
normal usage. The more the dryer is used,
the more often you should check the exhaust
system and vent hood for proper operation.
the exhaust system MUST terminate outside
the enclosure with the termination securely
fastened to the mobile home structure.
4.
Refer to previous sections in this guide for other
important exhaust venting system requirements.
5.
When installing a gas dryer into a mobile home,
a provision must be made for outside make up
air. This provision is to be not less than twice
the area of the dryer exhaust outlet.
6.
Installer MUST anchor this (1) dryer or (2) dryer
mounted on pedestal to the fl oor with approved
Mobile Home Installation Kit - P/N 137067200.
INCORRECT
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eimgd60jiwEwmed70jssEimgd60lss

Table of Contents