Sliding Door Handle Switch Test
1. Disconnect the 2P connector from the sliding door
handle switch (A).
2. Remove the two mounting screws from the switch.
Wire side of famale terminals
BLK
BLU
3. Check for continuity between the terminals in each
switch position according to the table.
Terminal
Position
A
B
4. If the continuity is not as specified, replace the
switch.
B
A
1
2
22-317