cleaning
Clean filter regularly. Dirty or clogged filters can greatly reduce
filtering ability and cause a number of system problems including
poor spray patterns, clogged spray tips, etc.
To clean the filter, shutoff system and relieve all system pressure.
See the Pressure Relief Procedure on page 9.
1. Remove filter cap (1).
2. Pull filter element with check ball (3) straight out of the
filter body (6).
3. Thoroughly clean inside filter body (6), filter element with
check ball (3) and filter cap (1) with appropriate solvent.
Use care in handling parts as dirt, debris, scratches or
nicks may prevent O-rings or gaskets from sealing.
The 920 Series Filter Elements filter from the inside out. Be
certain to clean the screen element thoroughly on the inside.
Soak in solvent to loosen hardened paint, etc. or replace.
© Titan Tool Inc. All rights reserved.
1
2
3
4
5
6
10
9
37
Outlet Manifold Filter assembly
ITEM
PaRT
DEScRIPTION
NO.
NO.
1
920-917
Filter cap assembly
2
920-103
Ball, S.S.
3
920-004
Screen, filter, 50 mesh
4
920-006
Gasket, PTFE (thick)
5
920-070
Gasket, PTFE (thin)
6
920-927
Body, filter (5000 psi)
7
812-003
Nipple, hex
8
227-027
Plug, pipe
9
227-033
Plug, pipe
10
703-137
Swivel fitting
Part No. 920-050 Filter Service Kit
ITEM
PaRT
DEScRIPTION
NO.
NO.
2
920-103
Ball
4
920-006
Gasket, PTFE
5
920-070
Gasket, PTFE
Specifications
Max. Working Pressure
Filter Area
Outlet Ports
Wetted parts
QTY
1
1
1
1
1
1
1
1
1
1
QTY.
1
1
1
5000 psi (345 bar)
18in
(116 cm
)
2
2
(1) 1/4" NPT (F) for
bleed valve
(1) 3/8" NPT (F) with
1/4 NPSM (M) hose
connection
(1) 3/8" NPT (F) plug for
additional gun hookup.
Carbon steel with
electroless nickel
and cadmium plating,
stainless steel, PTFE