Samsung RF265AARS RF266AARS RF26NBRS1RF265AABP RF266AABP RF26NBBP1RF265AAWP RF266AAWP RF26NBSH1RF265AASH RF266AASH Service Manual page 57

Bottom mount freezer
Table of Contents

Advertisement

TROUBLESHOOTING
5) If F Sensor has trouble
ERROR Code
DATA1.
Temperature table
** Measuring point of resistance value according to
Sensor **
F : CN30#3
CN75#1 measuring resistance value
** 0 : Short trouble /
: Open trouble
Refer to circuit diagram in the manual
Sensor MICOM/Connector number
Connector CN30#3(Red) to
F
CN1#3(Black) PCB typical Ground
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #52,
CN30#3(Red) and CN1#3(Black) from
PCB typical Ground part are similar.
Checking method of F Sensor resistance
CN30#3(Red)
CN75#1(Gray)
- Compare the temperature table after the measure
Start
Start
Are MAIN PCB
Connector CN30 to CN75
inserted correctly?
YES
YES
Is F Sensor
unit normal?
YES
YES
Is the voltage between
MAIN PCB Connector CN30#3(Red) to
CN1#3(Black) normal?
YES
YES
Is the input voltage of
IC01 MICOM #52 normal?
YES
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
Checking method of F Sensor voltage
- Measure the voltage of Sensor Check Point #1(IC01COM #52) on
PCB or CN30#3(Red)
CN1#3(Black)
- Compare the temperature table after the measure
Measuring voltage of CN30#3(Red)
CN1#3(Black) are below.
56
NO
Bad contact of connector/ insert correctly
NO
Replace temperature sensor
NO(0.6V > Measurement < 4.6V)
Recheck the wiring connection
NO
Check the iced-solder, solder
bridging, disturbed solder
typical PCB Ground
CN1#3(Black)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents