JVC AV-21B16 Service Manual page 17

Hide thumbs Also See for AV-21B16:
Table of Contents

Advertisement

4.8
ADJUSTMENT PROCEDURE
4.8.1 CHECK ITEM
Measuring
Item
instrument
B1 VOLTAGE
Signal
generator
DC voltmeter
4.8.2 TUNER / IF CIRCUIT
Measuring
Item
instrument
IF VCO
Signal
generator
Remote
control unit
VCO (CW)
***.**
TOO HIGH
ABOVE REFERENCE
JUST REFERENCE
BELOW REFERENCE
TOO LOW
AFT ADJUST
VCO ADJUST
FINE
DISP : EXIT
ADJUSTMENT AT THIS POINT
IS USELESS
1-18 (No.YA415)
Test point
Adjustment part
TP-B1 : 1-pin
TP-E : 5-pin
(S1 connector)
[MAIN PWB]
Test point
Adjustment part
[1. IF]
1. VCO
MHz
YELLOW
(
)
***
**
(
)
***
**
TOO HIGH
ABOVE REFERENCE
JUST REFERENCE
BELOW REFERENCE
TOO LOW
ADJUSTMENT POINT
Description
(1) Receive a whole black signal.
(2) Connect a DC voltmeter to 1-pin and 5-pin of S1
connector.
(3) Make sure that the voltage is DC116.2V±2.0V.
Description
• Please use a signal generator which frequency output is
correctly calibrated.
(1) Receive any broadcast.
(2) Select 1.IF from the SERVICE MENU.
(3) Select < 1.VCO >.
(4) Select VCO ADJUST with [MENU
(5) Press [MENU - / +] keys until the colour of the
characters TOO HIGH changes blue to yellow. Then
gradually press the [MENU - / +] keys until the TOO
LOW changes yellow. At this time, confirm that the
value of VCO ADJUST is near +00.
(6) Select AFT ADJUST with [MENU
(7) Press [MENU - / +] keys until the characters JUST
REFERENCE changes blue to yellow.
(8) Press the [DISPLAY] key three times to return to
normal screen.
/ ] key.
/ ] key.