Kenwood KRF-V7070D Service Manual page 16

Audio video surround receiver
Hide thumbs Also See for KRF-V7070D:
Table of Contents

Advertisement

BS
BT
(X14-7630-10) (A/11)
1G
11G
10G
9G
8G
7G
29.2V
WH78
1
1
FLAC
2
2
FLAC
J - 7
D791
+8V
3
3
X08 MVDD
X08-
CN1
4
4
POWER RLY
1/4
+5.4V
5
5
5V MINI
6
6
D GND
7
7
FAST OFF1
C845
0.01
X09-
CN1
Q842
2/4
IC84
AK-6
C794
0.01
C844
0.01
IC79
D842
R844
100K
J2
Q841
5V AVR
W
RESET
C793
0.01
J3
C842
0.047F5.5
C792
+
22u50
W
C841
+
1000u6.3
+
+5V
LED
DRIVER
IC74
(BOTTOM VIEW)
8
9
OUT5
OUT6
7
10
OUT4
OUT7
6
11
OUT3
OUT8
5
12
OUT2
OUT9
4
13
OUT1
OUT10
CN49
3
14
CLOCK
OUT11
FLAC
2
15
DATA
OUT12
FLAC
1
16
VSS
VDD
+5V
CN50
FLAC 1
FLAC
X08 MVDD
POWER RLY
+5V
5V MINI
D GND
FAST OFF1 7
BU
BV
6G
5G
4G
3G
2G
1G
EXCEPT
(Y) TYPE
J - 7
(Y) TYPE
ONLY
POWER
POWER
X08-
CN1
TRANSFORMER
TRANSFORMER
BLU
BLU
1/4
GRY
GRY
BLU
BLU
WHT
RED
RED
YEL
YEL
RED
RED
BRN
YEL
YEL
BLU
WHT
WHT
YEL
YEL
RED
RED
X09-
CN1
WHT
WHT
BLK
BLK
2/4
WHT
WHT
RED
RED
AK-6
(X14- ) (I/11)
W
W
W960
F2
K451
T1A L250V
CN22
CN21
RLY CONT.
D454
7.2V
R456
Q451
2.2K
C455
2200u6.3
+
T1
R453
8.4V
1
1/4W
D453
+8V
6
+5.5V AVR
5
1
IC45
2
D451
1
3
OUT
IN
+8V
GND
D452
R451
2
2
3
4
C104
5
100P
6
VR-7060/7070/7080/KRF-V7070D/V7070D-S (4/4)
KRF-V8070D/V8070D-S/X9070D/X9070D-S (4/4)
BW
BX
ANODE CONNECTION
1G
2G
3G
4G
5G
6-14G
P1
1-1
1-1
1-1
1-1
P2
2-1
2-1
2-1
2-1
P3
3-1
3-1
3-1
3-1
P4
4-1
4-1
4-1
4-1
P5
5-1
5-1
5-1
5-1
P6
1-2
1-2
1-2
1-2
P7
2-2
2-2
2-2
2-2
P8
3-2
3-2
3-2
3-2
P9
4-2
4-2
4-2
4-2
P10
5-2
5-2
5-2
5-2
P11
1-3
1-3
1-3
1-3
P12
2-3
2-3
2-3
2-3
P13
3-3
3-3
3-3
3-3
P14
4-3
4-3
4-3
4-3
P15
5-3
5-3
5-3
5-3
P16
1-4
1-4
1-4
1-4
P17
2-4
2-4
2-4
2-4
(X14- ) (J/11)
E
VOLTAGE SWITCH
SELECTOR
CN1
WH1
GRY
1
1
1
F3
WHT
2
2
2
T4A L250V
3
3
(X14-7630-10)
YEL
3
CN4
CN3
DESTINATION
MODEL NAME
COUNTRY
S1
KRF-V7070D-S
EUROPE
KRF-V7070D
EUROPE
KRF-V8070D-S
EUROPE
KRF-V8070D
EUROPE
W141
KRF-X9070D-S
EUROPE
BRN
4
EUROPE
220-
110-
KRF-X9070D
240V
120V
PX
BLU
5
U.S.A.
VR-7080
CANADA
U.S.A.
VR-7070
CANADA
U.S.A.
VR-7060
CANADA
(X14-7630-10)
DESTINATION
MODEL NAME
CN48
COUNTRY
KRF-V7070D-S
EUROPE
3
KRF-V7070D
EUROPE
2
KRF-V8070D-S
EUROPE
KRF-V8070D
EUROPE
1
KRF-X9070D-S
EUROPE
EUROPE
KRF-X9070D
CN47
PX
1
U.S.A.
VR-7080
CANADA
2
U.S.A.
VR-7070
CANADA
U.S.A.
VR-7060
CANADA
P2
(X14-7630-10)
DESTINATION
MODEL NAME
COUNTRY
KRF-V7070D-S
EUROPE
CN45
KRF-V7070D
EUROPE
KRF-V8070D-S
EUROPE
1
KRF-V8070D
EUROPE
2
KRF-X9070D-S
EUROPE
EUROPE
(K,P)
: AC120V 60Hz
KRF-X9070D
(Y)
: AC110-120V/220-240V~
PX
50/60Hz
U.S.A.
VR-7080
(E)
: AC230V~ 50Hz
CANADA
U.S.A.
VR-7070
CANADA
U.S.A.
(X14-) (K/11)
VR-7060
D
CANADA
(X14-7630-10)
S2
WH5
CN46
DESTINATION
MODEL NAME
1
2
1
COUNTRY
1
2
1
2
KRF-V7070D-S
EUROPE
KRF-V7070D
EUROPE
2
KRF-V8070D-S
EUROPE
POWER SWITCH
KRF-V8070D
EUROPE
KRF-X9070D-S
EUROPE
3
EUROPE
KRF-X9070D
PX
4
U.S.A.
VR-7080
CANADA
RECORDING LINE
U.S.A.
VR-7070
CANADA
SIGNAL LINE
U.S.A.
GND LINE
VR-7060
CANADA
+B
B LINE
B
B LINE
Y05-4700-10
BY
BZ
15G
16G
P18
3-4
3-4
3-4
3-4
1-1
1-1
1-1
P19
4-4
4-4
4-4
4-4
P20
5-4
5-4
5-4
5-4
2-1
2-1
2-1
P21
1-5
1-5
1-5
1-5
3-1
3-1
3-1
P22
2-5
2-5
2-5
2-5
4-1
4-1
4-1
P23
3-5
3-5
3-5
3-5
P24
4-5
4-5
4-5
4-5
5-1
5-1
5-1
P25
5-5
5-5
5-5
5-5
1-2
1-2
1-2
P26
1-6
1-6
1-6
1-6
P27
2-6
2-6
2-6
2-6
2-2
2-2
2-2
P28
3-6
3-6
3-6
3-6
3-2
3-2
3-2
P29
4-6
4-6
4-6
4-6
P30
5-6
5-6
5-6
5-6
4-2
4-2
4-2
P31
1-7
1-7
1-7
1-7
5-2
5-2
5-2
P32
2-7
2-7
2-7
2-7
P33
3-7
3-7
3-7
3-7
1-3
1-3
1-3
P34
4-7
4-7
4-7
4-7
2-3
2-3
2-3
P35
5-7
5-7
5-7
5-7
P36
3-3
3-3
3-3
P37
4-3
4-3
4-3
P38
5-3
5-3
5-3
1-1
2-1
3-1
4-1
5-1
1-4
1-4
1-4
2-4
2-4
2-4
1-2
2-2
3-2
4-2
5-2
1-3
2-3
3-3
4-3
5-3
1-4
2-4
3-4
4-4
5-4
1-5
2-5
3-5
4-5
5-5
1-6
2-6
3-6
4-6
5-6
1-7
2-7
3-7
4-7
5-7
(2G-16G)
C455,
C842 CN21,
UNIT No.
A
B
E
C
D
F
G
C105
C202
C452
C453
C841
ABB.
909
22
E1
3300u
2-73
YES
NO
NO
YES
NO
NO
YES
0.039
NO
NO
YES
YES
E7
25
E2
3300u
2-72
YES
NO
NO
YES
YES
NO
YES
0.039
NO
NO
YES
YES
25
E8
E3
3300u
2-71
YES
NO
YES
YES
YES
YES
NO
0.039
NO
NO
YES
YES
E9
25
3300u
Y1
2-91
NO
YES
YES
YES
YES
NO
NO
0.068
YES
NO
YES
YES
25
K8
3300u
0-10
NO
NO
YES
NO
YES
NO
NO
0.1
NO
YES
NO
NO
16
P8
K7
3300u
0-10
NO
NO
YES
NO
YES
NO
NO
0.1
NO
YES
NO
NO
P7
16
K6
3300u
0-11
NO
NO
NO
NO
YES
NO
YES
0.1
NO
YES
NO
NO
P6
16
R100,
UNIT No.
CN47 CN48
D741-745
F1
F2
IC90
J2
J3
J66
J68
K451
ABB.
R121
E1
B30-2651
250V
MN101C49
S76-
2-73
YES
NO
YES
NO
YES
NO
YES
NO
-05
GGS
0110-05
E7
T4A L
E2
B30-2651
250V
MN101C49
S76-
2-72
YES
NO
YES
NO
YES
YES NO
NO
E8
-05
T4A L
GGS
0110-05
E3
B30-2651
MN101C49
S76-
250V
2-71
YES
NO
YES
NO
YES
YES NO
YES
E9
-05
T4A L
GGP
0110-05
B30-2545
250V
MN101C49
S76-
Y1
2-91
NO
YES
YES
YES
NO
YES NO
YES
-05
GGP
0110-05
T4A L
K8
B30-2545
125V
MN101C49
S76-
0-10
YES
NO
NO
YES
NO
YES NO
YES
-05
GGP
0107-05
P8
10A
K7
B30-2545
MN101C49
S76-
125V
0-10
YES
NO
NO
YES
NO
YES
NO
YES
P7
-05
10A
GGP
0107-05
K6
B30-2545
125V
MN101C49
S76-
0-11
YES
NO
NO
YES
NO
YES NO
NO
-05
P6
10A
GGS
0107-05
R458, R835,
R867-
UNIT No.
R451
R454
R457
R881
R882
R884
R902
R914
R977
T1
ABB.
836
906
870
E1
L07-
2-73
130K
27
NO
NO
NO
100K
NO
NO
YES
YES
YES
27K
2761-05
E7
E2
L07-
2-72
130K
27
NO
NO
NO
100K
NO
NO
YES
YES
YES
27K
E8
2761-05
E3
L07-
2-71
130K
27
NO
NO
NO
100K
NO
NO
YES
YES
YES
27K
E9
2761-05
L07-
Y1
2-91
18K
15
NO
YES
YES
100K
NO
NO
YES
YES
NO
12K
2805-05
K8
L07-
0-10
39K
27
YES
NO
NO
100
NO
YES
YES
NO
NO
NO
P8
2809-05
K7
L07-
0-10
39K
27
YES
NO
NO
100
NO
YES
YES
NO
NO
NO
P7
2809-05
K6
L07-
0-11
39K
27
YES
NO
NO
100
YES
NO
NO
NO
NO
NO
2809-05
P6
W801-
UNIT No.
W104 W121
W804
W950
W951
W960
WH5
WH66
WH86
WH87
803
ABB.
E1
2-73
YES
NO
YES
YES
YES
NO
NO
YES
NO
NO
NO
E7
E2
2-72
YES
NO
YES
YES
NO
YES
NO
YES
YES
NO
NO
E8
E3
2-71
YES
NO
YES
YES
NO
NO
NO
YES
YES
YES
NO
E9
Y1
2-91
NO
NO
YES
YES
NO
NO
NO
YES
YES
NO
NO
K8
0-10
YES
YES
NO
NO
NO
NO
YES
NO
YES
NO
YES
P8
K7
NO
YES
NO
YES
0-10
YES
YES
NO
NO
NO
NO
YES
P7
K6
0-11
YES
YES
NO
YES
NO
YES
YES
NO
YES
NO
NO
P6
KRF-V7070D/V8070D/X9070D/VR-7060/7070/7080
CA
CB
3-4
3-4
3-4
4-4
4-4
4-4
5-4
5-4
5-4
1-5
1-5
1-5
2-5
2-5
2-5
3-5
3-5
3-5
4-5
4-5
4-5
5-5
5-5
5-5
1-6
1-6
1-6
2-6
2-6
2-6
3-6
3-6
3-6
4-6
4-6
4-6
5-6
5-6
5-6
1-7
1-7
1-7
2-7
2-7
2-7
3-7
3-7
3-7
4-7
4-7
4-7
5-7
5-7
5-7
CAUTION: For continued safety, replace
safety critical components only with manu-
facturer's recommended parts (refer to
parts list).
indicates safety critical com-
ponents. For continued protection against
risk of fire, replace only with same type and
rating fuse(s). To reduce the risk of electric
shock, leakage-current or resistance mea-
surements shall be carried out (exposed
parts are acceptably insulated from the
supply circuit) before the appliance is
returned to the customer.
The DC voltage is an actual reading mea-
sured with a high impedance type volt-
meter with no signal input. The measure-
ment value may vary depending on the
measuring instruments used or on the
product.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents