No.
Page
18
AUTO IRIS 2 IRIS WINDOW
19
GENLOCK
20
ND COMP
21
AUTO
SHADING
178
Menu List
Item
Settings
1/2/3/4/5/6/VAR Selects the auto iris detection window.
IRIS WINDOW
OFF/ON
IND
IRIS LEVEL
(–99 to 99)
IRIS APL RATIO
(–99 to 99)
IRIS VAR WIDTH
20 to 240 to 479 Adjusts the width of detection frame when the
IRIS VAR HEIGHT 20 to 135 to 269 Adjusts the height of detection frame when
IRIS VAR H POS
–460 to 0 to 459 Adjusts the horizontal position of detection
IRIS VAR V POS
–250 to 0 to 249 Adjusts the vertical position of detection
IRIS SPEED
(–99 to 99)
CLIP HIGH LIGHT OFF/ON
GENLOCK
OFF/ON
GL HD H PHASE
(–99 to 99)
GL SD H PHASE
(–99 to 99)
REFERENCE
INTERNAL/
GENLOCK/
SDI IN
ND OFFSET
OFF/ON
ADJUST
CLEAR ND
EXEC
OFFSET
AUTO BLK
EXEC
SHADING
RESET BLK SHD
EXEC
TEST OUT
VBS/Y/R/G/B/
SELECT
LCD
MASTER
–6dB/–3dB/0dB/
GAIN(TMP)
3dB/6dB/9dB/
12dB/18dB/
24dB/30dB/
36dB/42dB
Description
VAR: variable
Turns on and off the function which displays a
frame marker for the auto iris detection
window.
Adjusts the level of the auto iris target value.
Adjusts the mix ratio of auto iris detection
peak value and average value.
auto iris detection window is set to VAR.
the auto iris detection window is set to VAR.
frame when the auto iris detection window is
set to VAR.
frame when the auto iris detection window is
set to VAR.
Adjusts the auto iris speed.
Turns on and off the function which, during
auto iris adjustment, ignores very bright areas
by dulling the reaction to high luminescence.
Turns genlock on and off.
Sets the HD output H phase for genlock
operation.
Sets the SD output H phase for genlock
operation.
Displays the type of reference signal used by
this unit.
Turns on and off the mode which sets ND
(neutral density) filter color compensation
values.
Clear ND filter color compensation values.
Executes the auto black shading correction
function.
Clear black shading compensation values.
Selects the signal output of the TEST OUT
connector.
Temporarily sets the master gain value.