2.2.2 Wall Mounted Installations

For wall mounted installations, use only the Access Point bracket section and angle adjust bracket section if
required.
CAUTION
NOTE
NOTE
1. With the open slot connections facing down, attach the angle adjust bracket section at the desired
mounting location using four #10/32 lag bolts.
2. Using a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, attach (but don't tighten)
the Access Point bracket section to the AP-8163 with four M6 hex flange screws and insert two M6 hex
flange screws into the bottom holes on the sides of the Access Point bracket section.
Always mount the AP-8163 with the black gore vent facing down.
The U-bolt and band clamps are not included in the mounting bracket kit.
The lag bolts are not included in the mounting bracket kit.