Auto Changeover Operation - Fujitsu AS* G09LECB Service Instruction

Split type room air conditioner, wall mountedtype inverter
Table of Contents

Advertisement

4. AUTO CHANGEOVER OPERATION

When the air conditioner is set to the AUTO mode by remote control, operation starts in the optimum
mode from among the Heating, Cooling, Dry and Monitoring modes. During operation, the optimum
mode is automatically switched in accordance with temperature changes.
The temperature can be set between 18°C and 30°C in 1°C steps.
(Fig. 3 : Operation flow chart in Auto changeover)
Room temp.
NO
Room temp.
HEATING OPERATION
Thermostat remains
YES
in OFF state for 6 minutes or
YES
or operation command other than
auto changeover operation?
START
YES
>Ts+2°C ?
T
Setting temperature
NO
:
S
<Ts- 2°C ?
YES
longer?
NO
System stops
NO
COOLING OPERATION
Thermostat remains
in OFF state for 6 minutes or
longer?
NO
System stops
or operation command other than
auto changeover operation?
NO
01-04
YES
YES