REMOVING THE EVAPORATION PAN
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug refrigerator or disconnect power.
2.
Lift the condenser line out of the evapo-
ration pan bracket
3.
Release the 2 evaporation pan tabs in-
serted into the cabinet
4.
Release the 2 evaporation pan tabs in-
serted into the cabinet
5.
Tabs on the evaporation pan secure the
front of the pan to the base.
4-22