When Vertical Louver does not operate.
• Confirm that the Vertical Louver is normally geared with the shaft of
Stepping Motor.
• If the regular torque is detected when rotating the Vertical Louver with
hands
• Check the connecting condition of CN-UP/DOWN Connector
• Check the soldering condition(on PWB) of CN-UP/DOWN Connector
• Confirm that there is DC + 12V between pin (RED) of CN-UP/DOWN and
GND.
• Confirm that there is a soldering short at following terminals.
- Between
- Between
- Between
- Between
• Confirm the assembly conditions that are catching and interfering parts in
the rotation radial of the Vertical Louver
Normal
Check the operating circuit of the Vertical Louver
,
,
and
of MICOM
77
78
79
80
,
,
and
of IC02M
4
5
6
7
,
,
and
of IC01M
10
11
12
13
,
,
,
and
of CN-UP/DOWN
1
2
3
4
5
If there are no problems after above checks
Troubleshooting Guide
Service Manual 67