During Playback - Sony PDW-HD1200 Operation Manual

Professional disc recorder
Hide thumbs Also See for PDW-HD1200:
Table of Contents

Advertisement

Alarm message in time
data display area
Live Logg!
a) Displayed only when setup menu item 016 ALARM DISPLAY is set to
"on".
During recording operations
Alarm message in time
data display area
a)
Input Sig!"
a)
ILL. REC!
a)
ILL. REF!
a)
MEM. Full!
Verify ERR!
Recording
Cache Full!
a) Displayed only when setup menu item 016 ALARM DISPLAY is set to
"on" or "limit".

During playback

Alarm message in time data
display section
a)
ILL. PLAY!
a)
MEM. Empty!
Disc Error!
a) Displayed only when setup menu item 016 ALARM DISPLAY is set to
"on" or "limit".
152
Troubleshooting
Alarm message in video monitor screen Description/action
EXIT LIVE VIEW MODE OF LIVE
LOGGING.
Alarm message in video monitor screen Description/action
VIDEO INPUT SIGNAL DOES NOT
MATCH SYSTEM SETUP.
ENCODING DOES NOT SYNCHRONIZE
WITH REF VIDEO.
INPUT VIDEO SIGNAL DOES NOT
SYNCHRONIZE WITH REF VIDEO
SIGNAL.
USE COMMON REFERENCE SIGNAL
OR CONNECT RECORDER REF OUT TO
PLAYER REF IN.
MEMORY FULL !!
DISC ERROR DETECTED.
NOW RECORDING ...
CACHE FULL.
DATA IS BEING OVERWRITTEN.
Alarm message in monitor video
section
ILLEGAL PLAYBACK.
MEMORY EMPTY !!
DISC ERROR DETECTED.
This appears when an attempt is made to preset
timecode or establish a FAM or FTP connection while
the Live Logging function is set to Live View mode.
b) Displayed only when setup menu item 016 ALARM DISPLAY is set to
"on" or "limit".
This appears when the signal that does not
correspond to the system frequency or the number of
lines set in this unit is being input, or when HDSDI is
selected as a video input signal while setting the SD
signal recording.
Input a signal that matches the system frequency, or
change this unit's system frequency setting (see
page 38).
Check the signals being input to this unit.
Input a reference signal synchronized with this unit's
system frequency.
Check the disc being recorded by this unit.
This appears when an error is found in the signal
recorded on the disc while performing the recording
verification function. Change the disc.
Wait for recording to finish.
This appears when the memory becomes full while
performing the disc exchange cache function.
Change the disc immediately.
Description/action
Check the disc being played by this unit.
Check the disc being played by this unit.
Use another disc.

Hide quick links: