Safety clearances

Safety distance to the undershelf
It is not necessary to install an
undershelf underneath the cooktop.
If you do, however, install an
undershelf, you have to ensure a safety
distance between the upper edge of
the worktop and the upper edge of the
undershelf of at least 110 mm.
Make sure an air gap of at least 10 mm
is set between the back edge of the
undershelf and the back wall of the
cupboard for the connection cable.
If the cooktop has an external mains
connection box, the gap has to be at
least 30 mm.
44
Safety distance above the appliance
A minimum safety distance must be
maintained between the appliance and
the rangehood above it. See the
rangehood manufacturer's operating
and installation instructions for details.
If the manufacturer's instructions are
not available for the rangehood, a
minimum safety distance of at least
760 mm must be maintained.
For any flammable objects, e.g. utensil
rails, wall units etc., a minimum
distance of at least 760 mm must be
maintained between them and the
appliance below.
When two or more appliances are
installed together below a
rangehood, e.g. a gas wok and a
ceramic cooktop, which have
different safety distances given in
the installation instructions, you
should select the greater distance of
the two.