Download Print this page

Amana MSS9 Installation Instructions Manual: Upflow Model Installed Vertically; Drain Exiting Right Side; Drain Exiting Left Side; With Right Side Down

Single-stage gas furnace.
Hide thumbs

Advertisement

U
M
I
PFLOW
ODEL
NSTALLED
The trap and factory installed hoses remain as shipped.
The furnace drain may exit either the right or left side of
the furnace cabinet.
D
E
R
S
RAIN
XITING
IGHT
IDE
1. Locate and Install the 45º pipe / hose drain coupling
from the outside of the cabinet (barbed end goes in
the cabinet) through hole in the right side of the cabinet
and secure with two field supplied #8 self-tapping
screws (see Figure 21).
2. Locate the long drain hose #3 and cut at line "A" .
3. Install large end of hose #3 to trap outlet and secure
with 1.25" clamp.
4. Install smaller end of hose #3 on 45º elbow and secure
with 1" clamp.
5. Refer to Field Supplied Drain section for instructions
on field supplied / installed drain on outlet of furnace
trap.
D
E
L
S
RAIN
XITING
EFT
IDE
1. Install the 45 degree pipe / hose drain coupling from
the outside of the cabinet (barbed end goes in the
cabinet) through the hole in the left side of the cabinet and secure with two field supplied #8 self-tapping screws (see
Figure 21).
2. Locate the long drain hose #3 and cut at "B" line for a 17.5" cabinet; cut at line "C" for a 21" cabinet; do not cut for
a "D" width cabinet.
3. Install large end of hose #3 to trap outlet and secure with 1.25" clamp.
4. Install smaller end of hose #3 on 45º elbow and secure with 1" clamp.
5. Refer to Field Supplied Drain section for instructions on field supplied / installed drain on outlet of furnace trap.
U
M
I
PFLOW
ODEL
NSTALLED
D
OWN
Minimum 5 1/2" clearance is required for the drain trap be-
neath the furnace.
1. Remove the clamps from both ends of the drain hoses.
2. Remove the two screws holding the drain trap to the blower
deck.
3. Remove the trap and two hoses from the blower deck
4. Remove the two plugs from the right side of the cabinet
and install them in the blower deck.
5. (Draining the Vent Elbow ) Locate hose #5 and cut it at
line "C". Install the cut end of hose #5 from outside the
cabinet through the cabinet drain hole nearest the top.
Secure it to the barbed fitting in the elbow with a red
clamp.
6. (Draining the Collector Box) Install the non-grommet end
of hose #11 from outside the cabinet in the bottom drain
hole. Install on collector box and secure with a silver
clamp.
7. Use two silver clamps and secure the hoses to drain trap. The trap outlet faces the front of the furnace. Secure the
trap to the cabinet using two screws removed in step 2 by inserting the two screws through the large set of holes in the
top mounting tabs of the trap into the two predrilled holes in the side of the cabinet.
V
ERTICALLY
H
R
ORIZONTALLY WITH
IGHT
45 degree
barb-pipe
adapter
Installer selects right or left side drain
and installs this hose accordingly.
S
IDE
20
Figure 21
Hose #5-Cut at "C"
Hose #11
Figure 22
Hose #1
Hose #2
45 degree
barb-pipe
adapter

Advertisement

Troubleshooting

   Related Manuals for Amana MSS9

This manual also for:

Css9

Comments to this Manuals

Symbols: 0