Focal Point FLORENCE ELECTRIC P23E Installation And User Instructions Manual

Electric wall heater

Advertisement

Quick Links

FLORENCE ELECTRIC
ELECTRIC WALL HEATER
MODEL P23E
INSTALLATION AND USER INSTRUCTIONS
Read and understand these instructions completely before commencing any assembly or installation.
Check that all components are included in the pack.
Revision A - 06/08
Focal Point Fires plc, Christchurch, Dorset, BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e-mail: sales@focalpointfires.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLORENCE ELECTRIC P23E and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point FLORENCE ELECTRIC P23E

  • Page 1 Read and understand these instructions completely before commencing any assembly or installation. Check that all components are included in the pack. Revision A - 06/08 Focal Point Fires plc, Christchurch, Dorset, BH23 2BT Tel: 01202 499330 Fax: 01202 499326 www.focalpointfires.co.uk...
  • Page 2: Table Of Contents

    IMPORTANT THIS APPLIANCE MUST BE EARTHED The manufacturer declines all liabilities for injury to persons, or damage to property, resulting from failure to observe this regulation, and/or failure to follow or observe these instructions. © 2008 Focal Point Fires plc.
  • Page 3: Site Requirements

    If mounted into a fireplace surround, ensure that the minimum clearance distances to mantles and/or any shelves fitted above the appliance are as specified above. Note: the ability of any fireplace or surround to withstand prolonged moderate heat, eg 80°C must be assured. © 2008 Focal Point Fires plc.
  • Page 4: Unpacking The Appliance

    2. Be careful not to damage the spinner or lamp during removal. Fig 2 This allows access to the lower fixing position of the rear bracket attached to the back of the main case assembly. See figure 3 Lower fixing position Fig 3 © 2008 Focal Point Fires plc.
  • Page 5: Fixing The Appliance

    FORCE OF EARTHQUAKES, VIBRATION used are sufficient. AND OTHER EXTERNAL FORCES. Focal Point Fires plc. assumes absolutely no responsibility for injuries WARNING and damages that may occur due to improper installation or handling. The appliance should not be installed until all wet plastering and/or dry wall sanding and wall painting has been completed.
  • Page 6 2mm gap. See figure 7. Fig 7 Fig 6 Simply hang the facia panel onto the outer casing ensuring that the corresponding keyhole shaped holes engage the screwheads fully. © 2008 Focal Point Fires plc.
  • Page 7: Operating The Appliance

    The following procedure must be carried out before the fire can be operated again: 1. Unplug the power supply cable at the outlet socket and place all switches to off at the appliance. © 2008 Focal Point Fires plc.
  • Page 8: Maintenance - Lamp Replacement

    Test on a hidden part before cleaning. Clean only in the direction of the grain. Glass Facia Panel - This should only be cleaned using a suitable glass cleaner. Test on a small area first. © 2008 Focal Point Fires plc.
  • Page 9: Servicing

    Please Note : Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is owned by Focal Point Fires plc. You are not permitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc.
  • Page 10 Florence Electric - Appliance Views and Dimensions © 2008 Focal Point Fires plc.