Specifications; Standard Series Specifications - Toshiba 1400 Series Operation Manual

Toshiba 1400 series; 1400 plus series ups
Table of Contents

Advertisement

TOSHIBA
4.0

Specifications

4.1

Standard Series Specifications

Input
Battery
Battery backup time when fully charged
with 0.7 power factor and 77° F (25° C)
Output
Output voltage regulation
Output voltage waveform
Rated load power factor
Voltage transient characteristic
Rated output current (rms)
Maximum peak output current (peak)
Inverter overload capacity
Environment
Switches
Interface
Options
Software for unattended
RS232 ASCII interface board
(*) Battery backup time may vary depending on the operating conditions and ambient temperature at the
installation site.
(**) At 6000 ft (2000 m) above sea level, output capacity should be derated by 3%.
(***) An initial charge time of 24 hrs. is necessary to obtain proper battery performance level before unit is placed
in operation.
MODEL NUMBER
UC0A1A006C6
CAPACITY
600 VA (0.42 kW)
Input voltage
Single phase, 120 Vac, +10% to -30%
Input frequency
45 to 65 Hz
Input capacity
Input power factor
Approximate unity (0.98 to 1.0)
Battery rated voltage
8 mins. at full load (*)
24 mins. at half load (*) 24 mins. at half load (*) 30 mins. at half load (*)
Recharge time
Maximum 10 hrs to 100% (***)
Type of batteries
Sealed lead-acid
Output voltage
Single-phase, 120 volts
Less than +/- 3%, steady state
Output frequency
50/60 Hz +/- 0.1% in free-running mode (line sync range +/- 1.0%)
Computer-grade sine wave with less than 3.0% total harmonic
distortion with linear load
0.7 lagging (0.6 to 1.0)
+/- 10% under 100% load step change
150% for 60 seconds
Crest factor
3
Operating temperature
32 to 104° F (0 to 40° C), optimal at 77° F (25° C)
Storage temperature
-4 to 104° F (-20 to 40° C)
Operating humidity
30 to 90%, no condensation
Altitude(**)
Less than 3000 ft (1000 m) above sea level
External dimensions
7.06W x 20.44D x 14.63H in (179W x 519D x 371H mm)
Weight
60 lb (27.2 kg)
Acoustical noise
45 dB at max. output, measured 3.3 ft (1 m) from front panel
Efficiency (ac-dc-ac)
Bypass switch
Automatic bypass is provided when the run switch is in the off
position, if a fault occurs, or if an overload occurs
Transfer switch
Mechanical switch provided (transfer time: approx. 4 mS)
Novell (TM) local area
DB9 connector (dry contact)
network
Signals:(1)ac input present (NC) [ jumper selectable to (NO) ]
computer shutdown
Contact Toshiba for details on this option
Contact Toshiba for details on this option
External battery pack
Contact Toshiba for details on this option
UC0A1A008C6
800 VA (0.56 kW)
660 VA
880 VA
36 Vdc
48 Vdc
8 mins. at full load (*)
5.0A
6.6A
15.0A
19.8A
66 lb (29.9 kg)
89%
89%
(2)low battery (NO)
4 - 1
UC0A1A010C6
1000 VA (0.7 kW)
1100 VA
60 Vdc
10 mins. at full load (*)
8.3A
25.0A
70 lb (31.8 kg)